Author
Listed:
- Lisheng Li
(State Grid Shandong Electric Power Research Institute, Jinan 250003, China
Shandong Smart Grid Technology Innovation Center, Jinan 250003, China)
- Haidong Yu
(State Grid Shandong Electric Power Research Institute, Jinan 250003, China
Shandong Smart Grid Technology Innovation Center, Jinan 250003, China)
- Bin Wang
(National Key Laboratory of New Power System Operation and Control, Department of Electrical Engineering Tsinghua University, Haidian District, Beijing 100084, China)
- Yang Liu
(State Grid Shandong Electric Power Research Institute, Jinan 250003, China
Shandong Smart Grid Technology Innovation Center, Jinan 250003, China)
- Yuanyuan Lu
(National Key Laboratory of New Power System Operation and Control, Department of Electrical Engineering Tsinghua University, Haidian District, Beijing 100084, China)
- Wenbin Liu
(State Grid Shandong Electric Power Research Institute, Jinan 250003, China
Shandong Smart Grid Technology Innovation Center, Jinan 250003, China)
Abstract
Due to the demand for temporary rapid grid connection in renewable energy power plants, the topology structure of T-connected power lines has been widely used in the power grid. In this three-terminal system, fault localization is difficult because of traditional impedance-based or traveling wave-based fault localization methods; the three-terminal data should be synchronized and communicated. Since different terminal assets belong to different enterprises, it is actually difficult to maintain good synchronization between them. Therefore, in practical applications, the fault location of T-connected power lines often fails. This article proposes a single terminal fault location method for a T-connection power line to address this issue. It is based on the fact that the local topology of the T-connected power line in the healthy phase remains unchanged during the fault-clearing process. It utilizes the sequential current and voltage data changes generated by the sequential tripping ping emitted by the circuit breaker from different terminals to describe the constant topology of the healthy phase as an equation and calculates the accurate fault location after solving the equation. The Levenberg–Marquardt algorithm was used to calculate fault distance and transition resistance, and the effectiveness of this method was verified through simulation.
Suggested Citation
Lisheng Li & Haidong Yu & Bin Wang & Yang Liu & Yuanyuan Lu & Wenbin Liu, 2024.
"Sequential Data-Based Fault Location for Single-Line-to-Ground Fault in a T-Connection Power Line,"
Energies, MDPI, vol. 17(12), pages 1-13, June.
Handle:
RePEc:gam:jeners:v:17:y:2024:i:12:p:2975-:d:1416219
Download full text from publisher
Corrections
All material on this site has been provided by the respective publishers and authors. You can help correct errors and omissions. When requesting a correction, please mention this item's handle: RePEc:gam:jeners:v:17:y:2024:i:12:p:2975-:d:1416219. See general information about how to correct material in RePEc.
If you have authored this item and are not yet registered with RePEc, we encourage you to do it here. This allows to link your profile to this item. It also allows you to accept potential citations to this item that we are uncertain about.
We have no bibliographic references for this item. You can help adding them by using this form .
If you know of missing items citing this one, you can help us creating those links by adding the relevant references in the same way as above, for each refering item. If you are a registered author of this item, you may also want to check the "citations" tab in your RePEc Author Service profile, as there may be some citations waiting for confirmation.
For technical questions regarding this item, or to correct its authors, title, abstract, bibliographic or download information, contact: MDPI Indexing Manager (email available below). General contact details of provider: https://www.mdpi.com .
Please note that corrections may take a couple of weeks to filter through
the various RePEc services.