Author
Listed:
- Cristian-Eugeniu Sălceanu
(Research and Development Department, National Institute for Research, Development and Testing in Electrical Engineering—ICMET Craiova, 200746 Craiova, Romania)
- Sorin Enache
(Faculty of Electrical Engineering, University of Craiova, 200440 Craiova, Romania)
- Cătălin Dobrea
(Research and Development Department, National Institute for Research, Development and Testing in Electrical Engineering—ICMET Craiova, 200746 Craiova, Romania)
- Daniela Iovan
(Research and Development Department, National Institute for Research, Development and Testing in Electrical Engineering—ICMET Craiova, 200746 Craiova, Romania)
- Daniel Ocoleanu
(Research and Development Department, National Institute for Research, Development and Testing in Electrical Engineering—ICMET Craiova, 200746 Craiova, Romania)
- Marcel Nicola
(Research and Development Department, National Institute for Research, Development and Testing in Electrical Engineering—ICMET Craiova, 200746 Craiova, Romania)
- Ștefan Șeitan
(Research and Development Department, National Institute for Research, Development and Testing in Electrical Engineering—ICMET Craiova, 200746 Craiova, Romania)
- Mihai Ionescu
(Research and Development Department, National Institute for Research, Development and Testing in Electrical Engineering—ICMET Craiova, 200746 Craiova, Romania)
Abstract
If an R.M.U. (Ring Main Unit) cubicle is installed, operated and maintained in accordance with current standards and the manufacturer’s instructions, the likelihood of internal arcing is reduced, but should not be completely ignored. This article outlines the experimental situations in which arcing can occur and the catastrophic effects seen if R.M.U. is not properly designed for this type of damage. This type of failure can be caused by a fault, abnormal operating conditions or a malfunction and represents a danger during its installation and to persons present. The situations in which this type of failure can occur are presented and experimentally analysed: bi-phase internal arcing in the connections compartment, three-phase internal arcing in the switching compartment, internal arcing in the fuse compartment and single-phase arcing between a phase and the switchgear enclosure.
Suggested Citation
Cristian-Eugeniu Sălceanu & Sorin Enache & Cătălin Dobrea & Daniela Iovan & Daniel Ocoleanu & Marcel Nicola & Ștefan Șeitan & Mihai Ionescu, 2024.
"Experimental Study of the Behaviour of Ring Main Unit-Type Panels in the Event of Internal Arcing in Different Compartments,"
Energies, MDPI, vol. 17(11), pages 1-20, May.
Handle:
RePEc:gam:jeners:v:17:y:2024:i:11:p:2500-:d:1399992
Download full text from publisher
Corrections
All material on this site has been provided by the respective publishers and authors. You can help correct errors and omissions. When requesting a correction, please mention this item's handle: RePEc:gam:jeners:v:17:y:2024:i:11:p:2500-:d:1399992. See general information about how to correct material in RePEc.
If you have authored this item and are not yet registered with RePEc, we encourage you to do it here. This allows to link your profile to this item. It also allows you to accept potential citations to this item that we are uncertain about.
We have no bibliographic references for this item. You can help adding them by using this form .
If you know of missing items citing this one, you can help us creating those links by adding the relevant references in the same way as above, for each refering item. If you are a registered author of this item, you may also want to check the "citations" tab in your RePEc Author Service profile, as there may be some citations waiting for confirmation.
For technical questions regarding this item, or to correct its authors, title, abstract, bibliographic or download information, contact: MDPI Indexing Manager (email available below). General contact details of provider: https://www.mdpi.com .
Please note that corrections may take a couple of weeks to filter through
the various RePEc services.