IDEAS home Printed from https://ideas.repec.org/a/gam/jeners/v17y2024i11p2496-d1399786.html
   My bibliography  Save this article

Optimization Design Study of a Full-Range Charged Calibration Device for a Low-Voltage Current Transformer

Author

Listed:
  • Can Ding

    (College of Electrical Engineering and New Energy, China Three Gorges University, Yichang 443002, China)

  • Tingting Feng

    (College of Electrical Engineering and New Energy, China Three Gorges University, Yichang 443002, China)

  • Yaolong Bai

    (College of Electrical Engineering and New Energy, China Three Gorges University, Yichang 443002, China)

  • Yiji Shi

    (College of Electrical Engineering and New Energy, China Three Gorges University, Yichang 443002, China)

Abstract

According to standards, the harmonic content should be less than 5% at the time of calibration, while the calibration index proposed in this paper stipulates that the primary current amplitude of 1%~120% of the full range of the accuracy level reaches 0.05 S level. In view of the above problems and indexes, this paper adopts the active regulation technology of primary current; firstly, the harmonics of primary current are extracted, and then the opposite harmonic currents are injected by the penetrating wire to offset the harmonics, and finally, charged calibration is carried out. The inductive current transformer charged calibration device was first designed, and the particle swarm algorithm was used to optimize the offset performance of the key link of the background current offset suppression. The transfer function of the offset loop was derived, and it was theoretically analyzed that it can meet the offset requirements up to the 200th harmonic. The results show that the optimized calibration method can realize the full-range calibration of low-voltage inductive current transformers under charged conditions by making a prototype of the device and constructing a test circuit for experiments, and measuring the data and analyzing them.

Suggested Citation

  • Can Ding & Tingting Feng & Yaolong Bai & Yiji Shi, 2024. "Optimization Design Study of a Full-Range Charged Calibration Device for a Low-Voltage Current Transformer," Energies, MDPI, vol. 17(11), pages 1-13, May.
  • Handle: RePEc:gam:jeners:v:17:y:2024:i:11:p:2496-:d:1399786
    as

    Download full text from publisher

    File URL: https://www.mdpi.com/1996-1073/17/11/2496/pdf
    Download Restriction: no

    File URL: https://www.mdpi.com/1996-1073/17/11/2496/
    Download Restriction: no
    ---><---

    Corrections

    All material on this site has been provided by the respective publishers and authors. You can help correct errors and omissions. When requesting a correction, please mention this item's handle: RePEc:gam:jeners:v:17:y:2024:i:11:p:2496-:d:1399786. See general information about how to correct material in RePEc.

    If you have authored this item and are not yet registered with RePEc, we encourage you to do it here. This allows to link your profile to this item. It also allows you to accept potential citations to this item that we are uncertain about.

    We have no bibliographic references for this item. You can help adding them by using this form .

    If you know of missing items citing this one, you can help us creating those links by adding the relevant references in the same way as above, for each refering item. If you are a registered author of this item, you may also want to check the "citations" tab in your RePEc Author Service profile, as there may be some citations waiting for confirmation.

    For technical questions regarding this item, or to correct its authors, title, abstract, bibliographic or download information, contact: MDPI Indexing Manager (email available below). General contact details of provider: https://www.mdpi.com .

    Please note that corrections may take a couple of weeks to filter through the various RePEc services.

    IDEAS is a RePEc service. RePEc uses bibliographic data supplied by the respective publishers.