Author
Listed:
- Albe M. Bloul
(Department of Electrical and Computer Engineering, Dalhousie University, Halifax, NS B3H 4R2, Canada)
- Mohamad Abuhamdah
(Department of Electrical and Computer Engineering, Dalhousie University, Halifax, NS B3H 4R2, Canada)
- Adel M. Sharaf
(Department of Electrical and Computer Engineering, Dalhousie University, Halifax, NS B3H 4R2, Canada)
- Hamed H. Aly
(Department of Electrical and Computer Engineering, Dalhousie University, Halifax, NS B3H 4R2, Canada)
- Jason Gu
(Department of Electrical and Computer Engineering, Dalhousie University, Halifax, NS B3H 4R2, Canada)
Abstract
Nonlinear loads, crucial components of power system grids, pose a challenge due to harmonics injection. This work tackles this issue with a novel modified green plug–switched filter compensation scheme using fuzzy logic controllers. This innovative scheme presented in this paper utilizes dual action pulse width modulation to ensure switching functions from harmonics reduction and capacitive compensation for inrush nonlinear-type AC loads. The scheme’s multi-loop regulations and online switching effectively handle dynamic-type slow-acting inrush, motorized- and other rectifier-type nonlinear loads, enhancing the power factor, power quality at source and load buses, and reducing the total harmonics distortion at the key source and sensitive nonlinear load buses. A simulation model in the MATLAB/SIMULINK-2023b software environment demonstrates the efficiency of the proposed FACTS technique. The modulated dual mode switched filter-capacitive compensation scheme controlled by a fuzzy logic controller ensures less harmonics distortion and improved voltage stabilization. The results show that voltage, current, active power, reactive power, power factor regulation, and effective energy utilization are achievable with the designed Flexible AC Transmission System-Modulated Filter Capacitor Compensation–Switched Filter Compensator (FACTS-MFCC-SFC). The switched modulated AC green plug filter significantly improves power quality and enhances power factor in cases of inrush and nonlinear loads.
Suggested Citation
Albe M. Bloul & Mohamad Abuhamdah & Adel M. Sharaf & Hamed H. Aly & Jason Gu, 2024.
"An Efficient Shunt Modulated AC Green Plug–Switched Filter Compensation Scheme for Nonlinear Loads,"
Energies, MDPI, vol. 17(10), pages 1-25, May.
Handle:
RePEc:gam:jeners:v:17:y:2024:i:10:p:2426-:d:1397395
Download full text from publisher
Corrections
All material on this site has been provided by the respective publishers and authors. You can help correct errors and omissions. When requesting a correction, please mention this item's handle: RePEc:gam:jeners:v:17:y:2024:i:10:p:2426-:d:1397395. See general information about how to correct material in RePEc.
If you have authored this item and are not yet registered with RePEc, we encourage you to do it here. This allows to link your profile to this item. It also allows you to accept potential citations to this item that we are uncertain about.
We have no bibliographic references for this item. You can help adding them by using this form .
If you know of missing items citing this one, you can help us creating those links by adding the relevant references in the same way as above, for each refering item. If you are a registered author of this item, you may also want to check the "citations" tab in your RePEc Author Service profile, as there may be some citations waiting for confirmation.
For technical questions regarding this item, or to correct its authors, title, abstract, bibliographic or download information, contact: MDPI Indexing Manager (email available below). General contact details of provider: https://www.mdpi.com .
Please note that corrections may take a couple of weeks to filter through
the various RePEc services.