Abstract
In this paper, a new D-distance factor is proposed to determine the failure probability and to prioritize maintenance actions of power circuit breakers in high-voltage substations. The D-distance factor is calculated by using the condition index and renovation index of a high-voltage circuit breaker (HVCB). To facilitate effective decision-making on maintenance with a simple method and less computational effort, the proposed model incorporates the weighting–scoring method (WSM) and analytical hierarchy process (AHP) with the various diagnostic methods for condition index assessments as well as the operation requirements of HVCBs for renovation index assessments. Many significant parameters from circuit breaker testing, such as insulation resistance, contact resistance, contact timing, SF6 gas measurements, gas leakage rate, visual inspection, etc., have been considered for condition index determination. In addition to these, other significant parameters, such as age of the circuit breaker, age of the interrupter and mechanism, number of fault current interruptions, actual load current to rated current ratio, actual short circuit current to rated interrupting current ratio, maintenance ability, spare parts availability, maintenance expertise level, etc., are also considered for renovation index determination. To validate the proposed model, the practical test data of twenty 115 kV HVCBs in various substations of a distribution utility in Thailand were utilized and tested. By analyzing the actual condition and operation requirement of the circuit breaker, the output, as the condition index and renovation index using the proposed method, is discussed with HVCB experts in the utility to adjust the scores and weights of all criteria to obtain the most accurate and reliable model. The results show that the D-distance technique measured from the risk matrix, which is defined as the failure probability, can be used to rank the maintenance schedule from urgent to normal maintenance tasks. In addition, various failure probabilities in the risk matrix of the circuit breaker can be used to determine the appropriate maintenance strategies for the power circuit breaker in each group. Finally, the proposed method could help the utility managers and maintenance engineers manage the maintenance planning effectively and easily for thousands of HVCBs in the grid, and it can be further applied with other high-voltage equipment in both transmission and distribution systems to facilitate the maintenance activities according to available costs and human resources.
Suggested Citation
Suphon Kumpalavalee & Thanapong Suwanasri & Cattareeya Suwanasri & Rattanakorn Phadungthin, 2023.
"D-Distance Technique to Determine Failure Probability of Power Circuit Breaker,"
Energies, MDPI, vol. 16(2), pages 1-17, January.
Handle:
RePEc:gam:jeners:v:16:y:2023:i:2:p:847-:d:1032517
Download full text from publisher
Corrections
All material on this site has been provided by the respective publishers and authors. You can help correct errors and omissions. When requesting a correction, please mention this item's handle: RePEc:gam:jeners:v:16:y:2023:i:2:p:847-:d:1032517. See general information about how to correct material in RePEc.
If you have authored this item and are not yet registered with RePEc, we encourage you to do it here. This allows to link your profile to this item. It also allows you to accept potential citations to this item that we are uncertain about.
We have no bibliographic references for this item. You can help adding them by using this form .
If you know of missing items citing this one, you can help us creating those links by adding the relevant references in the same way as above, for each refering item. If you are a registered author of this item, you may also want to check the "citations" tab in your RePEc Author Service profile, as there may be some citations waiting for confirmation.
For technical questions regarding this item, or to correct its authors, title, abstract, bibliographic or download information, contact: MDPI Indexing Manager (email available below). General contact details of provider: https://www.mdpi.com .
Please note that corrections may take a couple of weeks to filter through
the various RePEc services.