Author
Listed:
- Daniel Kalús
(Department of Building Services, Faculty of Civil Engineering, Slovak University of Technology, 810 05 Bratislava, Slovakia)
- Veronika Mučková
(Department of Building Services, Faculty of Civil Engineering, Slovak University of Technology, 810 05 Bratislava, Slovakia)
- Daniela Koudelková
(Department of Building Services, Faculty of Civil Engineering, Slovak University of Technology, 810 05 Bratislava, Slovakia)
- Mária Kurčová
(Department of Building Services, Faculty of Civil Engineering, Slovak University of Technology, 810 05 Bratislava, Slovakia)
- Zuzana Straková
(Department of Building Services, Faculty of Civil Engineering, Slovak University of Technology, 810 05 Bratislava, Slovakia)
- Martin Sokol
(Department of Building Services, Faculty of Civil Engineering, Slovak University of Technology, 810 05 Bratislava, Slovakia)
- Rastislav Ingeli
(Department of Building Construction, Faculty of Civil Engineering, Slovak University of Technology, 810 05 Bratislava, Slovakia)
- Patrik Šťastný
(Department of Building Technology, Faculty of Civil Engineering, Slovak University of Technology, Radlinského 11, 810 05 Bratislava, Slovakia)
- Peter Janík
(Engineer in the Field of Energy Efficiency of Buildings, 851 05 Bratislava, Slovakia)
Abstract
This article is closely related to the oldest article titled Contribution to Active Thermal Protection Research—Part 1 Analysis of Energy Functions by Parametric Study. It is a continuation of research that focuses on verifying the energy potential and functions of so-called active thermal protection (ATP). As mentioned in the first part, the amount of thermal energy consumed for heating buildings is one of the main parameters that determine their future design, especially the technical equipment. The issue of reducing the consumption of this energy is implemented in various ways, such as passive thermal protection, i.e., by increasing the thermal insulation parameters of the individual materials of the building envelope or by optimizing the operation of the technical equipment of the buildings. On the other hand, there are also methods of active thermal protection that aim to reduce heat leakage through nontransparent parts of the building envelope. This methodology is based on the validation of the results of a parametric study of the dynamic thermal resistance (DTR) and the heat fluxes to the interior and exterior from the ATP for the investigated envelope of the experimental house EB2020 made of aerated concrete blocks, presented in the article “Contribution to the research on active thermal protection—Part 1, Analysis of energy functions by the parametric study”, by long-term experimental measurements. The novelty of the research lies in the involvement of variant-peak heat/cooling sources in combination with RES and in creating a new, original way of operating energy systems with the possibility of changing and combining the operating modes of the ATP. We have verified the operation of the experimental house in the energy functions of thermal barrier, heating/cooling with RES, and without RES and ATP. The energy saving when using RES and ATP is approximately 37%. Based on the synthesis and induction of analogous forms of the results of previous research into recommendations for the development of building envelopes with energy-active elements, we present further possible outcomes in the field of ATP, as well as already realized and upcoming prototypes of thermal insulation panels.
Suggested Citation
Daniel Kalús & Veronika Mučková & Daniela Koudelková & Mária Kurčová & Zuzana Straková & Martin Sokol & Rastislav Ingeli & Patrik Šťastný & Peter Janík, 2023.
"Contribution to Active Thermal Protection Research—Part 2 Verification by Experimental Measurement,"
Energies, MDPI, vol. 16(12), pages 1-33, June.
Handle:
RePEc:gam:jeners:v:16:y:2023:i:12:p:4595-:d:1166867
Download full text from publisher
Most related items
These are the items that most often cite the same works as this one and are cited by the same works as this one.
Corrections
All material on this site has been provided by the respective publishers and authors. You can help correct errors and omissions. When requesting a correction, please mention this item's handle: RePEc:gam:jeners:v:16:y:2023:i:12:p:4595-:d:1166867. See general information about how to correct material in RePEc.
If you have authored this item and are not yet registered with RePEc, we encourage you to do it here. This allows to link your profile to this item. It also allows you to accept potential citations to this item that we are uncertain about.
If CitEc recognized a bibliographic reference but did not link an item in RePEc to it, you can help with this form .
If you know of missing items citing this one, you can help us creating those links by adding the relevant references in the same way as above, for each refering item. If you are a registered author of this item, you may also want to check the "citations" tab in your RePEc Author Service profile, as there may be some citations waiting for confirmation.
For technical questions regarding this item, or to correct its authors, title, abstract, bibliographic or download information, contact: MDPI Indexing Manager (email available below). General contact details of provider: https://www.mdpi.com .
Please note that corrections may take a couple of weeks to filter through
the various RePEc services.