IDEAS home Printed from https://ideas.repec.org/a/gam/jeners/v16y2022i1p151-d1012973.html
   My bibliography  Save this article

Retrofit Proposals for Energy Efficiency and Thermal Comfort in Historic Public Buildings: The Case of the Engineering Faculty’s Seat of Sapienza University

Author

Listed:
  • Andrea Vallati

    (DIAEE—Department of Astronautical, Electrical and Energy Engineering, Sapienza University of Rome, Via Eudossiana 18, 00184 Rome, Italy)

  • Miriam Di Matteo

    (DIAEE—Department of Astronautical, Electrical and Energy Engineering, Sapienza University of Rome, Via Eudossiana 18, 00184 Rome, Italy)

  • Costanza Vittoria Fiorini

    (DIAEE—Department of Astronautical, Electrical and Energy Engineering, Sapienza University of Rome, Via Eudossiana 18, 00184 Rome, Italy)

Abstract

The building sector greatly contributes to energy consumption and Greenhouse Gas emissions, relating to the whole building life cycle. Boasting a huge building heritage of historical and architectural value, Europe faces challenging retrofit perspectives, as the potential for high energy efficiency has to be exploited while preserving the buildings’ original characteristics. The present work aims to feature the influence of a passive strategy on a heritage building in a mild climate. As historical its façade cannot be modified, its large glazing areas involve multiple issues, such as an increase in the heating ( Q H ) and cooling ( Q C ) energy demands and the risk of thermal discomfort. Thus, window replacement was proposed for retrofitting. A dynamic simulation model in TRNSYS was validated with experimental data collected by the continuous monitoring of walls of different thicknesses and orientations. Solutions from replacement with Double Glazing Units (DGUs) with improved thermal insulation, to internal shading activation were applied. All configurations were compared in terms of Q H , Q C , thermal performance of the building and user comfort (Fanger). Low-e DGU enabled the saving of up to 14% of the annual energy demand, and shading also offered good results in summer, reducing Q C by 19%. In summer, DGU involved a maximum PPD reduction of 10 units.

Suggested Citation

  • Andrea Vallati & Miriam Di Matteo & Costanza Vittoria Fiorini, 2022. "Retrofit Proposals for Energy Efficiency and Thermal Comfort in Historic Public Buildings: The Case of the Engineering Faculty’s Seat of Sapienza University," Energies, MDPI, vol. 16(1), pages 1-25, December.
  • Handle: RePEc:gam:jeners:v:16:y:2022:i:1:p:151-:d:1012973
    as

    Download full text from publisher

    File URL: https://www.mdpi.com/1996-1073/16/1/151/pdf
    Download Restriction: no

    File URL: https://www.mdpi.com/1996-1073/16/1/151/
    Download Restriction: no
    ---><---

    References listed on IDEAS

    as
    1. Bastien, Diane & Athienitis, Andreas K., 2015. "Methodology for selecting fenestration systems in heating dominated climates," Applied Energy, Elsevier, vol. 154(C), pages 1004-1019.
    Full references (including those not matched with items on IDEAS)

    Most related items

    These are the items that most often cite the same works as this one and are cited by the same works as this one.
    1. Al-Saadi, Saleh Nasser & Shaaban, Awni K., 2019. "Zero energy building (ZEB) in a cooling dominated climate of Oman: Design and energy performance analysis," Renewable and Sustainable Energy Reviews, Elsevier, vol. 112(C), pages 299-316.
    2. Bustamante, Waldo & Uribe, Daniel & Vera, Sergio & Molina, Germán, 2017. "An integrated thermal and lighting simulation tool to support the design process of complex fenestration systems for office buildings," Applied Energy, Elsevier, vol. 198(C), pages 36-48.
    3. Ahn, Jonghoon & Chung, Dae Hun & Cho, Soolyeon, 2018. "Energy cost analysis of an intelligent building network adopting heat trading concept in a district heating model," Energy, Elsevier, vol. 151(C), pages 11-25.
    4. Bastien, Diane & Athienitis, Andreas K., 2017. "Passive thermal energy storage, part 2: Design methodology for solaria and greenhouses," Renewable Energy, Elsevier, vol. 103(C), pages 537-560.

    Corrections

    All material on this site has been provided by the respective publishers and authors. You can help correct errors and omissions. When requesting a correction, please mention this item's handle: RePEc:gam:jeners:v:16:y:2022:i:1:p:151-:d:1012973. See general information about how to correct material in RePEc.

    If you have authored this item and are not yet registered with RePEc, we encourage you to do it here. This allows to link your profile to this item. It also allows you to accept potential citations to this item that we are uncertain about.

    If CitEc recognized a bibliographic reference but did not link an item in RePEc to it, you can help with this form .

    If you know of missing items citing this one, you can help us creating those links by adding the relevant references in the same way as above, for each refering item. If you are a registered author of this item, you may also want to check the "citations" tab in your RePEc Author Service profile, as there may be some citations waiting for confirmation.

    For technical questions regarding this item, or to correct its authors, title, abstract, bibliographic or download information, contact: MDPI Indexing Manager (email available below). General contact details of provider: https://www.mdpi.com .

    Please note that corrections may take a couple of weeks to filter through the various RePEc services.

    IDEAS is a RePEc service. RePEc uses bibliographic data supplied by the respective publishers.