Abstract
For high-precision thermocouple calibration, the uniformity of the temperature field provided by the metal temperature equalizing block is low, and the structure of the gas-controlled heat pipe is complex. In order to improve the thermocouple calibration equipment, heat pipe technology can be used to provide the stability and uniformity of the temperature field of the equipment. The concentric annular heat pipe (CAHP) is completely placed in the heating furnace to provide a uniform temperature field, and limited studies consider this heating mode for alkali metal CAHPs. Specifically, no information is available on the effect of heating temperatures on the temperature distribution of the internal pipe of potassium CAHP. In this study, a temperature comparison based on potassium CAHP for high-precision thermocouple calibration was manufactured. The temperature stability and temperature uniformity of CAHP were measured, and the effects of heating temperature and heating mode on the isothermal performance in the metering wells of CAHP were studied. The CAHP can provide a very stable and uniform temperature field. Under uniform heating at 400 °C, the maximum temperature difference within 16 cm was 0.174 °C. After adjusting the heating mode, the maximum temperature difference was within 16 cm 0.095 °C. The CAHP can effectively reduce the influence of heating temperature fluctuation on the temperature in the metering well; the maximum temperature change rate of the metering wells affected by the heating furnace temperature was 0.0942 °C/°C.
Suggested Citation
Hongzhe Zhang & Fang Ye & Hang Guo & Xiaoke Yan, 2022.
"Effects of Heating Temperature on the Isothermal Performance of a Potassium Concentric Annular Heat Pipe,"
Energies, MDPI, vol. 15(7), pages 1-13, March.
Handle:
RePEc:gam:jeners:v:15:y:2022:i:7:p:2367-:d:778444
Download full text from publisher
Corrections
All material on this site has been provided by the respective publishers and authors. You can help correct errors and omissions. When requesting a correction, please mention this item's handle: RePEc:gam:jeners:v:15:y:2022:i:7:p:2367-:d:778444. See general information about how to correct material in RePEc.
If you have authored this item and are not yet registered with RePEc, we encourage you to do it here. This allows to link your profile to this item. It also allows you to accept potential citations to this item that we are uncertain about.
We have no bibliographic references for this item. You can help adding them by using this form .
If you know of missing items citing this one, you can help us creating those links by adding the relevant references in the same way as above, for each refering item. If you are a registered author of this item, you may also want to check the "citations" tab in your RePEc Author Service profile, as there may be some citations waiting for confirmation.
For technical questions regarding this item, or to correct its authors, title, abstract, bibliographic or download information, contact: MDPI Indexing Manager (email available below). General contact details of provider: https://www.mdpi.com .
Please note that corrections may take a couple of weeks to filter through
the various RePEc services.