Author
Listed:
- Clemens Fuchs
(Department of Agriculture and Food Sciences, University of Applied Sciences, 17033 Neubrandenburg, Germany)
- Drees Meyer
(Department of Agriculture and Food Sciences, University of Applied Sciences, 17033 Neubrandenburg, Germany)
- Axel Poehls
(Department of Agriculture and Food Sciences, University of Applied Sciences, 17033 Neubrandenburg, Germany)
Abstract
A climate-friendly and CO 2 -neutral energy supply for agricultural farms is the subject of investigation of this study. The supply concerns the internal economy (buildings and animal husbandry) as well as the production of synthetic fuels for outdoor work (cultivation of the fields). This energy is in demand with many customers, e.g., the dairy cooperative Arla Foods, whose goal is the production of cow’s milk with net-zero CO 2 emissions by the year 2050. The operational energy system considered here included renewable electricity generation, covering electricity consumption in the cowshed, battery storage for times without electricity generation, the production of synthetic fuels and feeding into the public power grid. Fluctuations depending on the day and the season were taken into account for electricity at 15-min intervals and for fuel per calendar week for one year. The aim was to determine the necessary capacities of renewable energy (RE) generation systems and production systems for synthetic fuel, as well as an economic evaluation with the calculation of the energy costs per kWh and the break-evens for the capital expenses (CapEx). Two different scenarios were developed using the example of a survey dairy farm with an annual electricity consumption of approximately 80,000 kWh in the cowshed and an annual diesel consumption of 35,000 L, corresponding to 350,000 kWh for field work. To ensure the energy supply, Scenario 1 required a photovoltaic system (PV) on the roof with an output of 125 kWp, a 250 kW small wind turbine, a battery with a storage capacity of 2 kWh and synthetic fuel production with an output of 210 kW. Scenario 2 required a 200 kWp PV system on the roof and a 520 kWp PV system in the open fields, a battery with a 105 kWh storage capacity and a synthetic fuel production facility with an output of 385 kW to cover the farm’s energy needs. The results showed that a farm’s own electricity production is currently profitable; however, a farm’s production of synthetic fuel still has comparatively high costs and therefore is not yet profitable. Further technical advances, rising prices of fossil fuels and economies of scale, e.g., larger cooperatively-operated plants, could help new technology to make a breakthrough.
Suggested Citation
Clemens Fuchs & Drees Meyer & Axel Poehls, 2022.
"Production and Economic Assessment of Synthetic Fuels in Agriculture—A Case Study from Northern Germany,"
Energies, MDPI, vol. 15(3), pages 1-21, February.
Handle:
RePEc:gam:jeners:v:15:y:2022:i:3:p:1156-:d:742160
Download full text from publisher
Corrections
All material on this site has been provided by the respective publishers and authors. You can help correct errors and omissions. When requesting a correction, please mention this item's handle: RePEc:gam:jeners:v:15:y:2022:i:3:p:1156-:d:742160. See general information about how to correct material in RePEc.
If you have authored this item and are not yet registered with RePEc, we encourage you to do it here. This allows to link your profile to this item. It also allows you to accept potential citations to this item that we are uncertain about.
We have no bibliographic references for this item. You can help adding them by using this form .
If you know of missing items citing this one, you can help us creating those links by adding the relevant references in the same way as above, for each refering item. If you are a registered author of this item, you may also want to check the "citations" tab in your RePEc Author Service profile, as there may be some citations waiting for confirmation.
For technical questions regarding this item, or to correct its authors, title, abstract, bibliographic or download information, contact: MDPI Indexing Manager (email available below). General contact details of provider: https://www.mdpi.com .
Please note that corrections may take a couple of weeks to filter through
the various RePEc services.