Author
Listed:
- Salem K. Brini Ahmed
(Faculty of Mining and Energy Engineering, Sebha University, Sebha 00218, Libya)
- Aliyu M. Aliyu
(School of Engineering, University of Lincoln, Brayford Pool, Lincoln LN6 7TS, UK)
- Yahaya D. Baba
(Atmospheric Emissions Research Group, Cranfield University, Cranfield MK43 0AL, UK)
- Mukhtar Abdulkadir
(Department of Chemical Engineering, Federal University of Technology, Minna PMB 65, Nigeria)
- Rahil Omar Abdulhadi
(Faculty of Mining and Energy Engineering, Sebha University, Sebha 00218, Libya)
- Liyun Lao
(Centre for Thermal Energy Systems and Materials, Cranfield University, Cranfield MK43 0AL, UK)
- Hoi Yeung
(Centre for Thermal Energy Systems and Materials, Cranfield University, Cranfield MK43 0AL, UK)
Abstract
Gas injection is a frequently used method for artificial lift and flow regime rectification in offshore production and transportation flowlines. The flow behaviour in such flowlines is complex and a better understanding of flow characteristics, such as flow patterns, void fraction/hold up distributions and pressure gradient is always required for efficient and optimal design of downstream handling facilities. Injection method and location have been shown to strongly affect downstream fluid behaviour that can have important implications for pumping and downstream facility design, especially if the development length between pipeline and downstream facility is less than L/D = 50 as reported by many investigators. In this article, we provide the results of an experimental investigation into the effects of the gas injection position on the characteristics of the downstream upwards vertical gas flow using a vertical riser with an internal diameter of 52 mm and a length of 10.5 m. A horizontal 40-m-long section connected at the bottom provides options for riser base or horizontal flow line injection of gas. The flowline gas injection is performed 40 m upstream of the riser base. A 16 by 16 capacitance wire mesh sensor and a gamma densitometer were used to measure the gas-liquid phase cross-sectional distribution at the riser top. A detailed analysis of the flow characteristics is carried out based on the measurements. These include flow regimes, cross-sectional liquid holdup distributions and peaking patterns as well as analysis of the time series data. Our findings show that flow behaviours differences due to different gas injection locations were persisting after a development length of 180D in the riser. More specifically, core-peaking liquid holdup occurred at the lower gas injection rates through the flowline, while wall-peaking holdup profiles were established at the same flow conditions for riser base injection. Wall peaking was associated with dispersed bubbly flows and hence non-pulsating as against core-peaking was associated with Taylor bubbles and slug flows. Furthermore, it was found that the riser base injection generally produced lower holdups. It was noted that the circumferential injector used at the riser base promoted high void fraction and hence low liquid holdups. Due to the bubbly flow structure, the slip velocity is smaller than for larger cap bubbles and hence the void fraction is higher. The measurements and observations presented in the paper provides valuable knowledge on riser base/flowline gas introduction that can directly feed into the design of downstream facilities such as storage tanks, slug catchers and separators.
Suggested Citation
Salem K. Brini Ahmed & Aliyu M. Aliyu & Yahaya D. Baba & Mukhtar Abdulkadir & Rahil Omar Abdulhadi & Liyun Lao & Hoi Yeung, 2022.
"Comparative Analysis of Riser Base and Flowline Gas Injection on Vertical Gas-Liquid Two-Phase Flow,"
Energies, MDPI, vol. 15(19), pages 1-19, October.
Handle:
RePEc:gam:jeners:v:15:y:2022:i:19:p:7446-:d:938309
Download full text from publisher
Corrections
All material on this site has been provided by the respective publishers and authors. You can help correct errors and omissions. When requesting a correction, please mention this item's handle: RePEc:gam:jeners:v:15:y:2022:i:19:p:7446-:d:938309. See general information about how to correct material in RePEc.
If you have authored this item and are not yet registered with RePEc, we encourage you to do it here. This allows to link your profile to this item. It also allows you to accept potential citations to this item that we are uncertain about.
We have no bibliographic references for this item. You can help adding them by using this form .
If you know of missing items citing this one, you can help us creating those links by adding the relevant references in the same way as above, for each refering item. If you are a registered author of this item, you may also want to check the "citations" tab in your RePEc Author Service profile, as there may be some citations waiting for confirmation.
For technical questions regarding this item, or to correct its authors, title, abstract, bibliographic or download information, contact: MDPI Indexing Manager (email available below). General contact details of provider: https://www.mdpi.com .
Please note that corrections may take a couple of weeks to filter through
the various RePEc services.