IDEAS home Printed from https://ideas.repec.org/a/gam/jeners/v15y2022i16p5831-d885974.html
   My bibliography  Save this article

Peculiarities of Calculating the Thermal Conductivity of Moist Autoclaved Aerated Concrete

Author

Listed:
  • Beata Backiel-Brzozowska

    (Faculty of Civil Engineering and Environmental Sciences, Institute of Civil Engineering and Transport, Bialystok University of Technology, 45 Wiejska Str., 15-351 Bialystok, Poland)

  • Vadzim I. Nikitsin

    (Faculty of Mechanical Engineering, Brest State Technical University, 267 Moskovskaya Str., 224017 Brest, Belarus)

  • Abdrahman Alsabry

    (Faculty of Civil Engineering, Architecture and Environmental Engineering, Institute of Civil Engineering, University of Zielona Gora, 1 Prof. Z. Szafrana Str., 65-516 Zielona Gora, Poland)

  • Serafim K. Nikitsin

    (Faculty of Electronic Information Systems, Brest State Technical University, 267 Moskovskaya Str., 224017 Brest, Belarus)

  • Wioleta Rutkowska

    (Faculty of Civil Engineering and Environmental Sciences, Institute of Civil Engineering and Transport, Bialystok University of Technology, 45 Wiejska Str., 15-351 Bialystok, Poland)

Abstract

The pore space of autoclaved aerated concretes (ACCs), regardless of their apparent density, is represented by large pores formed as a result of gas formation and fine capillary pores. With the free absorption of liquid moisture, only the capillary pores are filled. Large pores contain vapor-air mixture. Considering such a bimodal pore size distribution, it is proposed to determine the thermal conductivity of moist ACC in two stages. First, an inhomogeneous ternary system that consists of a solid skeleton with a fine porous structure containing gas and liquid moisture should be considered. Then a binary system is taken into account, the first component of which is the mentioned ternary system, and the other component of which consists of isolated gas inclusions in large pores. To determine the thermal conductivity of the ternary system, the dependences constructed using the theory of generalized conductivity were used. The thermal conductivity of the binary system was calculated using well-known formulas. It was found that the results of thermal conductivity calculations based on the proposed two-step method deviate from the experimental data in the range from −7.29 to +5.75%, with an average deviation of −0.71%. With the one-step calculation method (assuming a unimodal pore distribution), the spread of analogous data ranges from −30.72 to −21.98%, with an average deviation of −26%.

Suggested Citation

  • Beata Backiel-Brzozowska & Vadzim I. Nikitsin & Abdrahman Alsabry & Serafim K. Nikitsin & Wioleta Rutkowska, 2022. "Peculiarities of Calculating the Thermal Conductivity of Moist Autoclaved Aerated Concrete," Energies, MDPI, vol. 15(16), pages 1-11, August.
  • Handle: RePEc:gam:jeners:v:15:y:2022:i:16:p:5831-:d:885974
    as

    Download full text from publisher

    File URL: https://www.mdpi.com/1996-1073/15/16/5831/pdf
    Download Restriction: no

    File URL: https://www.mdpi.com/1996-1073/15/16/5831/
    Download Restriction: no
    ---><---

    References listed on IDEAS

    as
    1. Abdrahman Alsabry & Beata Backiel-Brzozowska & Vadzim I. Nikitsin & Serafim K. Nikitsin, 2022. "Equations for Calculating the Thermal Conductivity of Capillary-Porous Materials with over Sorption Moisture Content," Sustainability, MDPI, vol. 14(10), pages 1-14, May.
    2. Abdrahman Alsabry & Beata Backiel-Brzozowska & Vadzim I. Nikitsin, 2020. "Dependencies for Determining the Thermal Conductivity of Moist Capillary-Porous Materials," Energies, MDPI, vol. 13(12), pages 1-14, June.
    Full references (including those not matched with items on IDEAS)

    Most related items

    These are the items that most often cite the same works as this one and are cited by the same works as this one.
    1. Abdrahman Alsabry & Beata Backiel-Brzozowska & Vadzim I. Nikitsin & Serafim K. Nikitsin, 2022. "Equations for Calculating the Thermal Conductivity of Capillary-Porous Materials with over Sorption Moisture Content," Sustainability, MDPI, vol. 14(10), pages 1-14, May.

    Corrections

    All material on this site has been provided by the respective publishers and authors. You can help correct errors and omissions. When requesting a correction, please mention this item's handle: RePEc:gam:jeners:v:15:y:2022:i:16:p:5831-:d:885974. See general information about how to correct material in RePEc.

    If you have authored this item and are not yet registered with RePEc, we encourage you to do it here. This allows to link your profile to this item. It also allows you to accept potential citations to this item that we are uncertain about.

    If CitEc recognized a bibliographic reference but did not link an item in RePEc to it, you can help with this form .

    If you know of missing items citing this one, you can help us creating those links by adding the relevant references in the same way as above, for each refering item. If you are a registered author of this item, you may also want to check the "citations" tab in your RePEc Author Service profile, as there may be some citations waiting for confirmation.

    For technical questions regarding this item, or to correct its authors, title, abstract, bibliographic or download information, contact: MDPI Indexing Manager (email available below). General contact details of provider: https://www.mdpi.com .

    Please note that corrections may take a couple of weeks to filter through the various RePEc services.

    IDEAS is a RePEc service. RePEc uses bibliographic data supplied by the respective publishers.