IDEAS home Printed from https://ideas.repec.org/a/gam/jeners/v14y2021i4p1133-d503022.html
   My bibliography  Save this article

The Energy-Saving Potential of Chilled Ceilings Combined with Personalized Ventilation

Author

Listed:
  • Aleksandra Lipczynska

    (Department of Heating, Ventilation and Dust Removal Technology, Faculty of Energy and Environmental Engineering, Silesian University of Technology, 44-100 Gliwice, Poland)

  • Jan Kaczmarczyk

    (Department of Heating, Ventilation and Dust Removal Technology, Faculty of Energy and Environmental Engineering, Silesian University of Technology, 44-100 Gliwice, Poland)

  • Arsen Melikov

    (International Centre for Indoor Environment and Energy, Department of Civil Engineering, Technical University of Denmark, DK-2800 Kgs. Lyngby, Denmark)

Abstract

The energy consumption of purely convective (i.e., various air volume (VAV) mixing ventilation) and combined radiant and convective HVAC systems (chilled ceiling combined with mixing ventilation—CCMV or personalized ventilation—CCPV) was investigated with multi-variant simulations carried out the IDA Indoor Climate and Energy software. We analyzed three different climates: temperate, hot and humid, and hot and dry. Our results show that the use of CCPV substantially reduced energy consumption compared to the conventional VAV system in hot climates. We also show that increasing the room temperature to 28 °C is an effective energy-saving strategy that can reduce consumption by as much as 40%. In the temperate climate, the VAV system was preferable because it used less energy as it benefited from outdoor air free-cooling. The control strategy of the supply temperature of personalized air had an impact on the energy demand of the HVAC system. The most efficient control strategy of the CCPV system was to increase the room temperature and keep the supply air temperature in the range of 20–22 °C. This approach consumed less energy than VAV or CCMV, and also improved the relative humidity in the hot climate.

Suggested Citation

  • Aleksandra Lipczynska & Jan Kaczmarczyk & Arsen Melikov, 2021. "The Energy-Saving Potential of Chilled Ceilings Combined with Personalized Ventilation," Energies, MDPI, vol. 14(4), pages 1-21, February.
  • Handle: RePEc:gam:jeners:v:14:y:2021:i:4:p:1133-:d:503022
    as

    Download full text from publisher

    File URL: https://www.mdpi.com/1996-1073/14/4/1133/pdf
    Download Restriction: no

    File URL: https://www.mdpi.com/1996-1073/14/4/1133/
    Download Restriction: no
    ---><---

    Corrections

    All material on this site has been provided by the respective publishers and authors. You can help correct errors and omissions. When requesting a correction, please mention this item's handle: RePEc:gam:jeners:v:14:y:2021:i:4:p:1133-:d:503022. See general information about how to correct material in RePEc.

    If you have authored this item and are not yet registered with RePEc, we encourage you to do it here. This allows to link your profile to this item. It also allows you to accept potential citations to this item that we are uncertain about.

    We have no bibliographic references for this item. You can help adding them by using this form .

    If you know of missing items citing this one, you can help us creating those links by adding the relevant references in the same way as above, for each refering item. If you are a registered author of this item, you may also want to check the "citations" tab in your RePEc Author Service profile, as there may be some citations waiting for confirmation.

    For technical questions regarding this item, or to correct its authors, title, abstract, bibliographic or download information, contact: MDPI Indexing Manager (email available below). General contact details of provider: https://www.mdpi.com .

    Please note that corrections may take a couple of weeks to filter through the various RePEc services.

    IDEAS is a RePEc service. RePEc uses bibliographic data supplied by the respective publishers.