IDEAS home Printed from https://ideas.repec.org/a/gam/jeners/v14y2021i1p205-d473929.html
   My bibliography  Save this article

Improved Procedure for Earth Fault Loop Impedance Measurement in TN Low-Voltage Network

Author

Listed:
  • Liviu Neamt

    (Electrical, Electronic and Computer Engineering Department, Technical University of Cluj-Napoca, 400114 Cluj-Napoca, Romania)

  • Alina Neamt

    (“Anghel Saligny” Technical College, 430295 Baia Mare, Romania)

  • Olivian Chiver

    (Electrical, Electronic and Computer Engineering Department, Technical University of Cluj-Napoca, 400114 Cluj-Napoca, Romania)

Abstract

The difficulties and uncertainties related to earth fault loop impedance measurement are addressed in this paper. Based on the presentation of the measurement procedure implemented in the test equipment (diagrams and measured quantities, respectively, interpretation of results), the shortcomings and errors that accompany it are highlighted. The position in the power system, the influence of power transformers, and the use of effective quantities instead of phasors are important sources of errors, but, as will be seen, the switching of loads at the consumer sides and/or the occurrence of fault regimes during measurements can lead to the most serious impairment of the accuracy in the impedance assessment. The clarification of these aspects is achieved, both starting from the equivalent diagrams of the measurement circuits and the analytical interpretation of the phenomena associated with the measurements, as well as based on the modeling and simulation of TN low-voltage electrical distribution networks, in a specialized program, Eaton xSpider, which allows the complete and complex analysis of a large number of scenarios. Thus, essential conclusions were drawn regarding the level of errors and their causes, obviously, with the research coming with solutions to be implemented at the level of the measurement protocols of the devices used.

Suggested Citation

  • Liviu Neamt & Alina Neamt & Olivian Chiver, 2021. "Improved Procedure for Earth Fault Loop Impedance Measurement in TN Low-Voltage Network," Energies, MDPI, vol. 14(1), pages 1-11, January.
  • Handle: RePEc:gam:jeners:v:14:y:2021:i:1:p:205-:d:473929
    as

    Download full text from publisher

    File URL: https://www.mdpi.com/1996-1073/14/1/205/pdf
    Download Restriction: no

    File URL: https://www.mdpi.com/1996-1073/14/1/205/
    Download Restriction: no
    ---><---

    Corrections

    All material on this site has been provided by the respective publishers and authors. You can help correct errors and omissions. When requesting a correction, please mention this item's handle: RePEc:gam:jeners:v:14:y:2021:i:1:p:205-:d:473929. See general information about how to correct material in RePEc.

    If you have authored this item and are not yet registered with RePEc, we encourage you to do it here. This allows to link your profile to this item. It also allows you to accept potential citations to this item that we are uncertain about.

    We have no bibliographic references for this item. You can help adding them by using this form .

    If you know of missing items citing this one, you can help us creating those links by adding the relevant references in the same way as above, for each refering item. If you are a registered author of this item, you may also want to check the "citations" tab in your RePEc Author Service profile, as there may be some citations waiting for confirmation.

    For technical questions regarding this item, or to correct its authors, title, abstract, bibliographic or download information, contact: MDPI Indexing Manager (email available below). General contact details of provider: https://www.mdpi.com .

    Please note that corrections may take a couple of weeks to filter through the various RePEc services.

    IDEAS is a RePEc service. RePEc uses bibliographic data supplied by the respective publishers.