IDEAS home Printed from https://ideas.repec.org/a/gam/jeners/v14y2021i16p4997-d614549.html
   My bibliography  Save this article

Failure Diagnosis and Root-Cause Analysis of In-Service and Defective Distribution Transformers

Author

Listed:
  • Saravanakumar Arumugam

    (Institute of Marine Engineering, University of Rostock, Justus-von-Liebig-Weg 2, 18059 Rostock, Germany)

Abstract

Diagnostic data of transformers are essential in determining their integrity and to estimate their reliability. Such diagnostic data is not available for distribution transformers as only meagre attempts are made to accumulate this information. The reason for lack of such attention is attributed to the compromise made to meet financial constraints and cost-cutting measures. It is needless to emphasize the significance of these diagnostic data in evading premature failures and enhancing the accuracy of the maintenance program. Overall, the concepts of diagnostic methods are well defined regarding power transformers, but cannot be extended to distribution transformers. This paper attempts to fill this gap by measuring the diagnostic data from in-service and defective distribution transformers. For this purpose, eight transformers (six in-service, two defective) showing deviations in their diagnostic status were selected from a group. As per their kVA rating and operating status, the chosen transformers were categorized into three sets and their integrity of insulation and winding-core arrangement were analyzed. Later, the root-cause analysis was performed on defective transformers to understand their failure reasons and possibilities to evade them. The pertinent data obtained are quite valuable for making decisions regarding reliability-oriented maintenance and for extending its potential in the distributed generation.

Suggested Citation

  • Saravanakumar Arumugam, 2021. "Failure Diagnosis and Root-Cause Analysis of In-Service and Defective Distribution Transformers," Energies, MDPI, vol. 14(16), pages 1-20, August.
  • Handle: RePEc:gam:jeners:v:14:y:2021:i:16:p:4997-:d:614549
    as

    Download full text from publisher

    File URL: https://www.mdpi.com/1996-1073/14/16/4997/pdf
    Download Restriction: no

    File URL: https://www.mdpi.com/1996-1073/14/16/4997/
    Download Restriction: no
    ---><---

    References listed on IDEAS

    as
    1. Cho, Namhun & Yun, Sangwon & Jung, Jaesung, 2019. "Determining the reverse fault current by the type of transformer and Distributed Generation in distribution system during the single-line to ground fault," Renewable and Sustainable Energy Reviews, Elsevier, vol. 109(C), pages 102-115.
    Full references (including those not matched with items on IDEAS)

    Citations

    Citations are extracted by the CitEc Project, subscribe to its RSS feed for this item.
    as


    Cited by:

    1. Kamil Lewandowski & Hubert Moranda & Radoslaw Szewczyk, 2023. "Bubble Effect Phenomenon in Modern Transformer Insulation Systems Using Aramid-Based Materials and Alternative Insulating Liquids," Energies, MDPI, vol. 16(14), pages 1-15, July.

    Most related items

    These are the items that most often cite the same works as this one and are cited by the same works as this one.
    1. Tang, Liangyu & Han, Yang & Zalhaf, Amr S. & Zhou, Siyu & Yang, Ping & Wang, Congling & Huang, Tao, 2024. "Resilience enhancement of active distribution networks under extreme disaster scenarios: A comprehensive overview of fault location strategies," Renewable and Sustainable Energy Reviews, Elsevier, vol. 189(PA).

    Corrections

    All material on this site has been provided by the respective publishers and authors. You can help correct errors and omissions. When requesting a correction, please mention this item's handle: RePEc:gam:jeners:v:14:y:2021:i:16:p:4997-:d:614549. See general information about how to correct material in RePEc.

    If you have authored this item and are not yet registered with RePEc, we encourage you to do it here. This allows to link your profile to this item. It also allows you to accept potential citations to this item that we are uncertain about.

    If CitEc recognized a bibliographic reference but did not link an item in RePEc to it, you can help with this form .

    If you know of missing items citing this one, you can help us creating those links by adding the relevant references in the same way as above, for each refering item. If you are a registered author of this item, you may also want to check the "citations" tab in your RePEc Author Service profile, as there may be some citations waiting for confirmation.

    For technical questions regarding this item, or to correct its authors, title, abstract, bibliographic or download information, contact: MDPI Indexing Manager (email available below). General contact details of provider: https://www.mdpi.com .

    Please note that corrections may take a couple of weeks to filter through the various RePEc services.

    IDEAS is a RePEc service. RePEc uses bibliographic data supplied by the respective publishers.