Zero-Sequence Differential Current Protection Scheme for Converter Transformer Based on Waveform Correlation Analysis

Author

Listed:
  • Tao Zheng

    (State Key Laboratory of Alternate Electrical Power System with Renewable Energy Sources, North China Electric Power University, Beijing 102206, China)

  • Xinhui Yang

    (State Key Laboratory of Alternate Electrical Power System with Renewable Energy Sources, North China Electric Power University, Beijing 102206, China)

  • Xingchao Guo

    (State Key Laboratory of Alternate Electrical Power System with Renewable Energy Sources, North China Electric Power University, Beijing 102206, China)

  • Xingguo Wang

    (State Key Laboratory of Power Grid Safety and Energy Conservation, China Electric Power Research Institute Co., Ltd, Beijing 100192, China)

  • Chengqi Zhang

    (State Key Laboratory of Alternate Electrical Power System with Renewable Energy Sources, North China Electric Power University, Beijing 102206, China)

Abstract

Through the analysis of the recovery inrush current generated by the external fault removal of the converter transformer, it is pointed out that the zero-sequence current caused by the recovery inrush may result in the saturation of the neutral current transformer (CT), whose measurement distortion contributes to the mis-operation of zero-sequence differential current protection. In this paper, a new scheme of zero-sequence differential current protection based on waveform correlation is proposed. By analyzing the characteristics of zero-sequence current under internal fault, external fault and external fault removal, the waveform correlation of the zero-sequence current measured at the terminal of the transformer and the zero-sequence current measured at the neutral point of the transformer is used for identification. The polarity of the CT is selected to guarantee the zero-sequence currents at the terminal and neutral point of the transformer exhibit a "ride through" characteristic under external fault, then the waveform similarity is high, and the correlation coefficient is positive. On the other hand, when internal fault occurs, zero-sequence current waveforms on both sides differ from each other largely, and the correlation coefficient is negative. Through a large number of simulations verified by PSCAD/EMTDC, this criterion can accurately identify internal and external faults, exempt from effects of the recovery inrush. Moreover, it presents certain ability for CT anti-saturation.

Suggested Citation

  • Tao Zheng & Xinhui Yang & Xingchao Guo & Xingguo Wang & Chengqi Zhang, 2020. "Zero-Sequence Differential Current Protection Scheme for Converter Transformer Based on Waveform Correlation Analysis," Energies, MDPI, vol. 13(7), pages 1-14, April.
  • Handle: RePEc:gam:jeners:v:13:y:2020:i:7:p:1814-:d:343287
    as

    Download full text from publisher

    File URL: https://www.mdpi.com/1996-1073/13/7/1814/pdf
    Download Restriction: no

    File URL: https://www.mdpi.com/1996-1073/13/7/1814/
    Download Restriction: no
    ---><---

    Citations

    Citations are extracted by the CitEc Project, subscribe to its RSS feed for this item.
    as


    Cited by:

    1. Sunil Kumar Gunda & Venkata Samba Sesha Siva Sarma Dhanikonda, 2021. "Discrimination of Transformer Inrush Currents and Internal Fault Currents Using Extended Kalman Filter Algorithm (EKF)," Energies, MDPI, vol. 14(19), pages 1-20, September.
    2. Seyed Amir Hosseini & Ali Akbar Nazari & Behrooz Taheri & Farzad Razavi & Hamed Hashemi-Dezaki, 2022. "Proposing a New Approach to Generate the Differential Trajectory of the Differential Relays Using COMTRADE Files," Sustainability, MDPI, vol. 14(21), pages 1-25, October.
    3. Jingde Xia & Shaozhuo Li & Shuping Gao & Wenquan Shao & Guobing Song & Changjiang Chen, 2021. "Research on Differential Protection of Generator Based on New Braking Mode," Energies, MDPI, vol. 14(7), pages 1-16, March.

    Corrections

    All material on this site has been provided by the respective publishers and authors. You can help correct errors and omissions. When requesting a correction, please mention this item's handle: RePEc:gam:jeners:v:13:y:2020:i:7:p:1814-:d:343287. See general information about how to correct material in RePEc.

    If you have authored this item and are not yet registered with RePEc, we encourage you to do it here. This allows to link your profile to this item. It also allows you to accept potential citations to this item that we are uncertain about.

    We have no bibliographic references for this item. You can help adding them by using this form .

    If you know of missing items citing this one, you can help us creating those links by adding the relevant references in the same way as above, for each refering item. If you are a registered author of this item, you may also want to check the "citations" tab in your RePEc Author Service profile, as there may be some citations waiting for confirmation.

    For technical questions regarding this item, or to correct its authors, title, abstract, bibliographic or download information, contact: MDPI Indexing Manager (email available below). General contact details of provider: https://www.mdpi.com .

    Please note that corrections may take a couple of weeks to filter through the various RePEc services.

    IDEAS is a RePEc service. RePEc uses bibliographic data supplied by the respective publishers.