IDEAS home Printed from https://ideas.repec.org/a/gam/jeners/v13y2020i5p1142-d327971.html
   My bibliography  Save this article

Non-Contact Measurement and Analysis of Trapped Charge Decay Rates for Cable Line Switching Transients

Author

Listed:
  • Stephen Robson

    (School of Engineering, Cardiff University, Cardiff CF24 3AA, UK)

  • Abderrahmane Haddad

    (School of Engineering, Cardiff University, Cardiff CF24 3AA, UK)

  • Simon Dennis

    (National Grid, Warwick CV34 6DA, UK)

  • Foroozan Ghassemi

    (National Grid, Warwick CV34 6DA, UK)

Abstract

During reclosure of 275 kV cable circuits used for voltage control, excessive overvoltages were observed on the network. Such events cause onerous and costly failures. Transient simulations have shown that the normal voltage on its own cannot generate such excessive switching overvoltages. Initial investigations by the network operator pointed towards trapped charge on the unearthed as the cause of the failures. Measurement of these trapped charge voltages and their slow decay without interfering with the charge has, to the author’s knowledge, not been done before in an operational substation. This work introduces a technique to measure trapped charge at a 275 kV substation using the Electrostatic Field Mill. Since the electric field is a proxy measurement of surface voltage, field mills can also be used to measure voltage. In this paper, an on-site substation measurement setup using an electrostatic field mill has been developed for the non-contact measurement of trapped charge voltage on a 275 kV underground cable circuit following switching operations at a National Grid substation. Results of field measurements within the substation and laboratory experimentation are discussed. It is demonstrated that with adequate calibration, achieved by using the known pre-switching power frequency steady state voltage, the slowly decaying DC voltage caused by the cable trapped charge can be measured using this non-contact technique. The correlation between the instantaneous time constant and the relative humidity is also analysed.

Suggested Citation

  • Stephen Robson & Abderrahmane Haddad & Simon Dennis & Foroozan Ghassemi, 2020. "Non-Contact Measurement and Analysis of Trapped Charge Decay Rates for Cable Line Switching Transients," Energies, MDPI, vol. 13(5), pages 1-19, March.
  • Handle: RePEc:gam:jeners:v:13:y:2020:i:5:p:1142-:d:327971
    as

    Download full text from publisher

    File URL: https://www.mdpi.com/1996-1073/13/5/1142/pdf
    Download Restriction: no

    File URL: https://www.mdpi.com/1996-1073/13/5/1142/
    Download Restriction: no
    ---><---

    Corrections

    All material on this site has been provided by the respective publishers and authors. You can help correct errors and omissions. When requesting a correction, please mention this item's handle: RePEc:gam:jeners:v:13:y:2020:i:5:p:1142-:d:327971. See general information about how to correct material in RePEc.

    If you have authored this item and are not yet registered with RePEc, we encourage you to do it here. This allows to link your profile to this item. It also allows you to accept potential citations to this item that we are uncertain about.

    We have no bibliographic references for this item. You can help adding them by using this form .

    If you know of missing items citing this one, you can help us creating those links by adding the relevant references in the same way as above, for each refering item. If you are a registered author of this item, you may also want to check the "citations" tab in your RePEc Author Service profile, as there may be some citations waiting for confirmation.

    For technical questions regarding this item, or to correct its authors, title, abstract, bibliographic or download information, contact: MDPI Indexing Manager (email available below). General contact details of provider: https://www.mdpi.com .

    Please note that corrections may take a couple of weeks to filter through the various RePEc services.

    IDEAS is a RePEc service. RePEc uses bibliographic data supplied by the respective publishers.