Analysis of a High-Voltage Room Quasi-Smoke Gas Explosion

Author

Listed:
  • Marit Sigfrid Bakka

    (Corporate Accident Investigations, Equinor, 5253 Sandsli, Norway)

  • Erling Kristian Handal

    (Corporate Accident Investigations, Equinor, 5253 Sandsli, Norway)

  • Torgrim Log

    (Department of Safety, Chemistry and Biomedical Laboratory Science, Fire Disaster Research Group, Western Norway University of Applied Sciences, 5528 Haugesund, Norway
    Kårstø Gas Processing Plant, Equinor, 5565 Kårstø, Norway)

Abstract

During an air separation unit shut-down in a methanol production plant, a stop signal was sent to the control cabinet of a synchronous motor for a booster compressor. The control cabinet stopped magnetizing the rotor, while the system logic ensured that the power circuit breakers for the start reactor coils were opened, in order to be ready for the next start-up. Unintentionally, the circuit breaker was still connected (i.e., power was let through the reactors for a prolonged time period), which led to extensive overheating. Subsequently, the central control room received an unaddressed sub-station smoke alarm, and plant operators were sent out to locate the possible source of smoke. The accessible rooms were searched, and traces of smoke were confirmed. The Emergency Response Organization (ERO) was mustered and, through inspection, the Emergency Response Team (ERT) realized that the smoke originated from a ground floor high-voltage room. Fire hoses were arranged for fire extinguishing, and the ERT withdrew to wait for the room to be electrically isolated. About one minute after briefly opening the only set of doors to the high-voltage room, flames were observed, and a quasi-smoke gas explosion violently forced both door blades open and released a substantial fire ball. Personnel had been in the risk zone shortly before the explosion, but luckily no personnel were hit by the slamming door blades or the emerging flames. The incident revealed several learning points related to improper maintenance, ambiguous smoke alarm, lack of flame detectors in the high-voltage room, insufficient risk understanding and training regarding electrically related fire incidents, and the absence of an automatic fire suppression system. In plants processing hydrocarbons, the safety focus regarding hydrocarbon fire and explosion risk is paramount. However, risks related to electrical accidents and compartment fire dynamics (e.g., backdraft and smoke gas explosion) should also be given proper attention.

Suggested Citation

  • Marit Sigfrid Bakka & Erling Kristian Handal & Torgrim Log, 2020. "Analysis of a High-Voltage Room Quasi-Smoke Gas Explosion," Energies, MDPI, vol. 13(3), pages 1-14, January.
  • Handle: RePEc:gam:jeners:v:13:y:2020:i:3:p:601-:d:314291
    as

    Download full text from publisher

    File URL: https://www.mdpi.com/1996-1073/13/3/601/pdf
    Download Restriction: no

    File URL: https://www.mdpi.com/1996-1073/13/3/601/
    Download Restriction: no
    ---><---

    References listed on IDEAS

    as
    1. Hong-Keun Ji & Guoming Wang & Woo-Hyun Kim & Gyung-Suk Kil, 2018. "Optimal Design of a Band Pass Filter and an Algorithm for Series Arc Detection," Energies, MDPI, vol. 11(4), pages 1-13, April.
    2. Guoming Wang & Woo-Hyun Kim & Gyung-Suk Kil & Dae-Won Park & Sung-Wook Kim, 2019. "An Intelligent Lightning Warning System Based on Electromagnetic Field and Neural Network," Energies, MDPI, vol. 12(7), pages 1-11, April.
    Full references (including those not matched with items on IDEAS)

    Citations

    Citations are extracted by the CitEc Project, subscribe to its RSS feed for this item.
    as


    Cited by:

    1. Torgrim Log & Amalie Gunnarshaug, 2022. "Analysis of a Costly Fiberglass-Polyester Air Filter Fire," Energies, MDPI, vol. 15(20), pages 1-16, October.
    2. Xiaoqin Hu & Arjen Kraaijeveld & Torgrim Log, 2020. "Numerical Investigation of the Required Quantity of Inert Gas Agents in Fire Suppression Systems," Energies, MDPI, vol. 13(10), pages 1-15, May.

    Most related items

    These are the items that most often cite the same works as this one and are cited by the same works as this one.
    1. Qiwei Lu & Zeyu Ye & Yilei Zhang & Tao Wang & Zhixuan Gao, 2019. "Analysis of the Effects of Arc Volt–Ampere Characteristics on Different Loads and Detection Methods of Series Arc Faults," Energies, MDPI, vol. 12(2), pages 1-16, January.
    2. Kiyoto Takenaka & Yusuke Ishikawa & Yukio Mizuno & Wenyi Lin, 2020. "Arc Discharge–Induced Ignition of Combustibles Placed on a Damaged AC Power Supply Cord," Energies, MDPI, vol. 13(3), pages 1-15, February.
    3. Qiongfang Yu & Yaqian Hu & Yi Yang, 2019. "Identification Method for Series Arc Faults Based on Wavelet Transform and Deep Neural Network," Energies, MDPI, vol. 13(1), pages 1-12, December.
    4. Hong-Keun Ji & Guoming Wang & Gyung-Suk Kil, 2020. "Optimal Detection and Identification of DC Series Arc in Power Distribution System on Shipboards," Energies, MDPI, vol. 13(22), pages 1-16, November.
    5. Rohana Rohana & Surya Hardi & Nasaruddin Nasaruddin & Yuwaldi Away & Andri Novandri, 2024. "Multi-Stage ANN Model for Optimizing the Configuration of External Lightning Protection and Grounding Systems," Energies, MDPI, vol. 17(18), pages 1-25, September.
    6. Hong-Keun Ji & Sung-Wook Kim & Gyung-Suk Kil, 2020. "Phase Analysis of Series Arc Signals for Low-Voltage Electrical Devices," Energies, MDPI, vol. 13(20), pages 1-14, October.

    Corrections

    All material on this site has been provided by the respective publishers and authors. You can help correct errors and omissions. When requesting a correction, please mention this item's handle: RePEc:gam:jeners:v:13:y:2020:i:3:p:601-:d:314291. See general information about how to correct material in RePEc.

    If you have authored this item and are not yet registered with RePEc, we encourage you to do it here. This allows to link your profile to this item. It also allows you to accept potential citations to this item that we are uncertain about.

    If CitEc recognized a bibliographic reference but did not link an item in RePEc to it, you can help with this form .

    If you know of missing items citing this one, you can help us creating those links by adding the relevant references in the same way as above, for each refering item. If you are a registered author of this item, you may also want to check the "citations" tab in your RePEc Author Service profile, as there may be some citations waiting for confirmation.

    For technical questions regarding this item, or to correct its authors, title, abstract, bibliographic or download information, contact: MDPI Indexing Manager (email available below). General contact details of provider: https://www.mdpi.com .

    Please note that corrections may take a couple of weeks to filter through the various RePEc services.

    IDEAS is a RePEc service. RePEc uses bibliographic data supplied by the respective publishers.