IDEAS home Printed from https://ideas.repec.org/a/gam/jeners/v13y2020i24p6625-d462612.html
   My bibliography  Save this article

A Portable System for the Evaluation of the Degree of Pollution of Transmission Line Insulators

Author

Listed:
  • Lucas de Paula Santos Petri

    (High Voltage Laboratory (Federal University of Itajubá—LAT-EFEI), Itajubá, MG 37500-903, Brazil)

  • Emanuel Antonio Moutinho

    (Equatorial Energia, São Luís, MA 65070-900, Brazil)

  • Rondinele Pinheiro Silva

    (Equatorial Energia, São Luís, MA 65070-900, Brazil)

  • Renato Massoni Capelini

    (HVEX, Itajubá, MG 37502-508, Brazil)

  • Rogério Salustiano

    (HVEX, Itajubá, MG 37502-508, Brazil)

  • Guilherme Martinez Figueiredo Ferraz

    (HVEX, Itajubá, MG 37502-508, Brazil)

  • Estácio Tavares Wanderley Neto

    (High Voltage Laboratory (Federal University of Itajubá—LAT-EFEI), Itajubá, MG 37500-903, Brazil)

  • Jansen Paula Villibor

    (High Voltage Laboratory (Federal University of Itajubá—LAT-EFEI), Itajubá, MG 37500-903, Brazil)

  • Suzana Silva Pinto

    (High Voltage Laboratory (Federal University of Itajubá—LAT-EFEI), Itajubá, MG 37500-903, Brazil)

Abstract

Surface pollution is a major cause of partial discharges in high voltage insulators in coastal cities, leading to degradation of their surface and accelerating their aging process, which may cause visible arcing, flashovers and system faults. Thus, this work provides a methodology for the assessment of the condition of insulators based on an instrument which generates a severity degree to help the electric utility team schedule maintenance routines for the structures that really need it. The instrument uses a Raspberry Pi board as the processing core, a PicoScope oscilloscope for the data acquisition and an antenna as a partial discharge sensor. The algorithms are implemented in Python, and use artificial intelligence tools, such as a convolutional network and a fuzzy inference system. Laboratory test methods for the simulation of the field pollution conditions were successfully used for the validation of the instrument, which showed a good correlation between the pollution level and the severity degree generated. In addition to that, field collected data were also used for the evaluation of the proposed severity degree, which is demonstrated to be consistent when compared with the utility’s reports and the history of the selected areas from where data were collected.

Suggested Citation

  • Lucas de Paula Santos Petri & Emanuel Antonio Moutinho & Rondinele Pinheiro Silva & Renato Massoni Capelini & Rogério Salustiano & Guilherme Martinez Figueiredo Ferraz & Estácio Tavares Wanderley Neto, 2020. "A Portable System for the Evaluation of the Degree of Pollution of Transmission Line Insulators," Energies, MDPI, vol. 13(24), pages 1-26, December.
  • Handle: RePEc:gam:jeners:v:13:y:2020:i:24:p:6625-:d:462612
    as

    Download full text from publisher

    File URL: https://www.mdpi.com/1996-1073/13/24/6625/pdf
    Download Restriction: no

    File URL: https://www.mdpi.com/1996-1073/13/24/6625/
    Download Restriction: no
    ---><---

    Citations

    Citations are extracted by the CitEc Project, subscribe to its RSS feed for this item.
    as


    Cited by:

    1. Luqman Maraaba & Khaled Al-Soufi & Twaha Ssennoga & Azhar M. Memon & Muhammed Y. Worku & Luai M. Alhems, 2022. "Contamination Level Monitoring Techniques for High-Voltage Insulators: A Review," Energies, MDPI, vol. 15(20), pages 1-32, October.

    Corrections

    All material on this site has been provided by the respective publishers and authors. You can help correct errors and omissions. When requesting a correction, please mention this item's handle: RePEc:gam:jeners:v:13:y:2020:i:24:p:6625-:d:462612. See general information about how to correct material in RePEc.

    If you have authored this item and are not yet registered with RePEc, we encourage you to do it here. This allows to link your profile to this item. It also allows you to accept potential citations to this item that we are uncertain about.

    We have no bibliographic references for this item. You can help adding them by using this form .

    If you know of missing items citing this one, you can help us creating those links by adding the relevant references in the same way as above, for each refering item. If you are a registered author of this item, you may also want to check the "citations" tab in your RePEc Author Service profile, as there may be some citations waiting for confirmation.

    For technical questions regarding this item, or to correct its authors, title, abstract, bibliographic or download information, contact: MDPI Indexing Manager (email available below). General contact details of provider: https://www.mdpi.com .

    Please note that corrections may take a couple of weeks to filter through the various RePEc services.

    IDEAS is a RePEc service. RePEc uses bibliographic data supplied by the respective publishers.