Author
Listed:
- Cheng-Hung Huang
(Department of Systems and Naval Mechatronic Engineering, National Cheng Kung University, Tainan 701, Taiwan)
- Chih-Yang Kuo
(Department of Systems and Naval Mechatronic Engineering, National Cheng Kung University, Tainan 701, Taiwan)
Abstract
A non-linear three-dimensional inverse shape design problem was investigated for a pipe type heat exchanger to estimate the design variables of continuous lateral ribs on internal Z-shape lateral fins for maximum thermal performance factor η. The design variables were considered as the positions, heights, and number of ribs while the physical properties of air were considered as a polynomial function of temperature; this makes the problem non-linear. The direct problem was solved using software package CFD-ACE+, and the Levenberg–Marquardt method (LMM) was utilized as the optimization tool because it has been proven to be a powerful algorithm for solving inverse problems. Z-shape lateral fins were found to be the best thermal performance among Z-shape, S-shape, and V-shape lateral fins. The objective of this study was to include continuous lateral ribs to Z-shape lateral fins to further improve η. Firstly, the numerical solutions of direct problem were solved using both polynomial and constant air properties and then compared with the corrected solutions to verify the necessity for using polynomial air properties. Then, four design cases, A, B, C and D, based on various design variables were conducted numerically, and the resultant η values were computed and compared. The results revealed that considering continuous lateral ribs on the surface of Z-shape lateral fins can indeed improve η value at the design working condition Re = 5000. η values of designs A, B and C were approximately 13% higher than that for Z-shape lateral fins, however, when the rib numbers were increased, i.e., design D, the value of η became only 11.5 % higher. This implies that more ribs will not guarantee higher η value.
Suggested Citation
Cheng-Hung Huang & Chih-Yang Kuo, 2020.
"A Nonlinear Inverse Design Problem for a Pipe Type Heat Exchanger Equipped with Internal Z-Shape Lateral Fins and Ribs,"
Energies, MDPI, vol. 13(23), pages 1-18, December.
Handle:
RePEc:gam:jeners:v:13:y:2020:i:23:p:6424-:d:457033
Download full text from publisher
Corrections
All material on this site has been provided by the respective publishers and authors. You can help correct errors and omissions. When requesting a correction, please mention this item's handle: RePEc:gam:jeners:v:13:y:2020:i:23:p:6424-:d:457033. See general information about how to correct material in RePEc.
If you have authored this item and are not yet registered with RePEc, we encourage you to do it here. This allows to link your profile to this item. It also allows you to accept potential citations to this item that we are uncertain about.
We have no bibliographic references for this item. You can help adding them by using this form .
If you know of missing items citing this one, you can help us creating those links by adding the relevant references in the same way as above, for each refering item. If you are a registered author of this item, you may also want to check the "citations" tab in your RePEc Author Service profile, as there may be some citations waiting for confirmation.
For technical questions regarding this item, or to correct its authors, title, abstract, bibliographic or download information, contact: MDPI Indexing Manager (email available below). General contact details of provider: https://www.mdpi.com .
Please note that corrections may take a couple of weeks to filter through
the various RePEc services.