IDEAS home Printed from https://ideas.repec.org/a/gam/jeners/v13y2020i22p6000-d446498.html
   My bibliography  Save this article

Thermo-Fluid Dynamics Analysis of Fire Smoke Dispersion and Control Strategy in Buildings

Author

Listed:
  • Ricardo S. Gomez

    (Postgraduate Program in Mechanical Engineering, Federal University of Paraiba, João Pessoa 58051-900, PB, Brazil)

  • Túlio R. N. Porto

    (Department of Mechanical Engineering, Federal University of Campina Grande, Campina Grande 58429-900, PB, Brazil)

  • Hortência L. F. Magalhães

    (Department of Chemical Engineering, Federal University of Campina Grande, Campina Grande 58429-900, PB, Brazil)

  • Antonio C. Q. Santos

    (Department of Mechanical Engineering, Federal University of Campina Grande, Campina Grande 58429-900, PB, Brazil)

  • Victor H. V. Viana

    (Postgraduate Program in Security Engineering, University Center of Patos (UNIFIP), Campina Grande 58416-440, PB, Brazil)

  • Kelly C. Gomes

    (Postgraduate Program in Mechanical Engineering, Federal University of Paraiba, João Pessoa 58051-900, PB, Brazil
    Department of Renewable Energy Engineering, Federal University of Paraiba, João Pessoa 58051-900, PB, Brazil)

  • Antonio G. B. Lima

    (Department of Mechanical Engineering, Federal University of Campina Grande, Campina Grande 58429-900, PB, Brazil)

Abstract

Smoke is the main threat of death in fires. For this reason, it becomes extremely important to understand the dispersion of this pollutant and to verify the influence of different control systems on its spread through buildings, in order to avoid or minimize its effects on living beings. Thus, this work aims to perform thermo-fluid dynamic study of smoke dispersion in a closed environment. All numerical analysis was performed using the Fire Dynamics Simulator (FDS) software. Different simulations were carried out to evaluate the influence of the exhaust system (natural or mechanical), the heat release rate (HRR), ventilation and the smoke curtain in the pollutant dispersion. Results of the smoke layer interface height, temperature profile, average exhaust volumetric flow rate, pressure and velocity distribution are presented and discussed. The results indicate that an increase in the natural exhaust area increases the smoke layer interface height, only for the well-ventilated compartment (open windows); an increase in the HRR accelerates the downward vertical displacement of the smoke layer and that the 3 m smoke curtain is efficient in exhausting smoke, only in the case of poorly ventilated compartments (i.e., with closed windows).

Suggested Citation

  • Ricardo S. Gomez & Túlio R. N. Porto & Hortência L. F. Magalhães & Antonio C. Q. Santos & Victor H. V. Viana & Kelly C. Gomes & Antonio G. B. Lima, 2020. "Thermo-Fluid Dynamics Analysis of Fire Smoke Dispersion and Control Strategy in Buildings," Energies, MDPI, vol. 13(22), pages 1-27, November.
  • Handle: RePEc:gam:jeners:v:13:y:2020:i:22:p:6000-:d:446498
    as

    Download full text from publisher

    File URL: https://www.mdpi.com/1996-1073/13/22/6000/pdf
    Download Restriction: no

    File URL: https://www.mdpi.com/1996-1073/13/22/6000/
    Download Restriction: no
    ---><---

    Citations

    Citations are extracted by the CitEc Project, subscribe to its RSS feed for this item.
    as


    Cited by:

    1. Pengcheng Qin & Mingnian Wang & Zhanwen Chen & Guanfeng Yan & Tao Yan & Changling Han & Anmin Wang, 2021. "Effects of Ambient Pressure on Burning Characteristics of Gasoline: A Pilot Study," Energies, MDPI, vol. 14(15), pages 1-12, July.
    2. Teng-Yi Wang & Kuang-Chung Tsai, 2021. "Effects of Time to Unactuate Air Conditioning on Fire Growth," Energies, MDPI, vol. 14(11), pages 1-15, May.
    3. Benedetto Nastasi & Francesco Mancini, 2021. "Procedures and Methodologies for the Control and Improvement of Energy-Environmental Quality in Construction," Energies, MDPI, vol. 14(9), pages 1-2, April.
    4. Marek Podkul & Jiri Pokorny & Lenka Brumarova & Dagmar Dlouha & Zuzana Heinzova & Katerina Kubricka & Dawid Szurgacz & Miroslav Fanta, 2022. "New Calculation Technique for Assessment of Smoke Layer Interface in Large Buildings in Connection with the Design of Buildings in the Czech Republic," Sustainability, MDPI, vol. 14(11), pages 1-18, May.

    Corrections

    All material on this site has been provided by the respective publishers and authors. You can help correct errors and omissions. When requesting a correction, please mention this item's handle: RePEc:gam:jeners:v:13:y:2020:i:22:p:6000-:d:446498. See general information about how to correct material in RePEc.

    If you have authored this item and are not yet registered with RePEc, we encourage you to do it here. This allows to link your profile to this item. It also allows you to accept potential citations to this item that we are uncertain about.

    We have no bibliographic references for this item. You can help adding them by using this form .

    If you know of missing items citing this one, you can help us creating those links by adding the relevant references in the same way as above, for each refering item. If you are a registered author of this item, you may also want to check the "citations" tab in your RePEc Author Service profile, as there may be some citations waiting for confirmation.

    For technical questions regarding this item, or to correct its authors, title, abstract, bibliographic or download information, contact: MDPI Indexing Manager (email available below). General contact details of provider: https://www.mdpi.com .

    Please note that corrections may take a couple of weeks to filter through the various RePEc services.

    IDEAS is a RePEc service. RePEc uses bibliographic data supplied by the respective publishers.