Abstract
The multiterminal flexible DC (MTDC) distribution system has become a hot research topic for its advantages such as new energy load accessibility and high reliability of power supply. However, the fault current during short-circuit faults will be more complicated and serious because of the multiple operating modes and specific converter structure in MTDC distribution system. The high fault current will affect the safety of equipment and system operation. As a result, it is necessary to study the fault current generation mechanism and current limiting method of the DC distribution system. In this paper, the generation mechanism, transient characteristics, and the influencing factors of the fault current in the DC breaker during the short-circuit faults are analyzed by theoretical analysis and simulations separately based on a ±10 kV three-terminal flexible DC distribution system. The current limiting devices are analyzed, and its configuration position and parameter calculation method are proposed. On this basis, the parameters of the current limiting reactor and its effects on each position are analyzed by electromagnetic transient simulations. The current limiting scheme is proposed and its reliability is verified. The study results can provide some reference for overcurrent analysis and current limiting measures of the multiterminal DC distribution system.
Suggested Citation
Jinghan Zhang & Yuqun Gao & Fanglei Xiao & Fang Guo & Xinwei Li & Yongxia Han & Licheng Li, 2019.
"Study on DC Breaker Fault Current and Its Limiting Method of Multiterminal Flexible DC Distribution System,"
Energies, MDPI, vol. 12(5), pages 1-15, March.
Handle:
RePEc:gam:jeners:v:12:y:2019:i:5:p:859-:d:211023
Download full text from publisher
Corrections
All material on this site has been provided by the respective publishers and authors. You can help correct errors and omissions. When requesting a correction, please mention this item's handle: RePEc:gam:jeners:v:12:y:2019:i:5:p:859-:d:211023. See general information about how to correct material in RePEc.
If you have authored this item and are not yet registered with RePEc, we encourage you to do it here. This allows to link your profile to this item. It also allows you to accept potential citations to this item that we are uncertain about.
We have no bibliographic references for this item. You can help adding them by using this form .
If you know of missing items citing this one, you can help us creating those links by adding the relevant references in the same way as above, for each refering item. If you are a registered author of this item, you may also want to check the "citations" tab in your RePEc Author Service profile, as there may be some citations waiting for confirmation.
For technical questions regarding this item, or to correct its authors, title, abstract, bibliographic or download information, contact: MDPI Indexing Manager (email available below). General contact details of provider: https://www.mdpi.com .
Please note that corrections may take a couple of weeks to filter through
the various RePEc services.