Abstract

This manuscript presents a comprehensive literature review with the aim to provide readers a reference document with up-to-date information on the field of methanol use as a chemical marker. It has been a little more than a decade since methanol was first introduced as a marker for assessing solid insulation condition in power transformers. It all started when methanol was identified in the laboratory during thermal ageing tests carried out with oil-immersed insulating papers and was subsequently also identified in transformer field samples. The first publication on the subject was released in 2007 by our research group. This review covers the methanol fundamentals such as the analytical methods for its determination in transformer oil, which is generally performed by headspace gas chromatography with mass spectrometry or flame ionization as a detector. Current standardization efforts for its determination include ASTM working group 30948 and IEC TC10. Kinetic studies have confirmed the relationship between methanol generation, the number of broken 1,4-β-glycosidic bonds of cellulose and changes in mechanical properties. Laboratory tests have confirmed its stability at different accelerated ageing temperatures. Several utilities have identified methanol during field measurements, case studies on power and some distribution transformers are presented, as well as transformer postmortem investigations. These field-testing results demonstrate its utility in monitoring cellulosic insulation degradation. Recently, a model of methanol interpretation has become available that allows for evaluation of the average degree of polymerization of core type transformer cellulose winding. Methanol has a role as an indicator of cellulosic solid insulation ageing in transformer mineral oil, and it is expected that in the future it will be in routine use by utilities.

Suggested Citation

  • Jocelyn Jalbert & Esperanza M. Rodriguez-Celis & Oscar H. Arroyo-Fernández & Steve Duchesne & Brigitte Morin, 2019. "Methanol Marker for the Detection of Insulating Paper Degradation in Transformer Insulating Oil," Energies, MDPI, vol. 12(20), pages 1-30, October.
  • Handle: RePEc:gam:jeners:v:12:y:2019:i:20:p:3969-:d:278094
    as

    Download full text from publisher

    File URL: https://www.mdpi.com/1996-1073/12/20/3969/pdf
    Download Restriction: no

    File URL: https://www.mdpi.com/1996-1073/12/20/3969/
    Download Restriction: no
    ---><---

    Citations

    Citations are extracted by the CitEc Project, subscribe to its RSS feed for this item.
    as


    Cited by:

    1. Draginja Mihajlovic & Vladimir Ivancevic & Valentina Vasovic & Jelena Lukic, 2022. "Cellulose Degradation and Transformer Fault Detection by the Application of Integrated Analyses of Gases and Low Molecular Weight Alcohols Dissolved in Mineral Oil," Energies, MDPI, vol. 15(15), pages 1-12, August.
    2. Andrew Adewunmi Adekunle & Samson Okikiola Oparanti & Issouf Fofana, 2023. "Performance Assessment of Cellulose Paper Impregnated in Nanofluid for Power Transformer Insulation Application: A Review," Energies, MDPI, vol. 16(4), pages 1-32, February.
    3. Yiyi Zhang & Yi Li & Shizuo Li & Hanbo Zheng & Jiefeng Liu, 2020. "A Molecular Dynamics Study of the Generation of Ethanol for Insulating Paper Pyrolysis," Energies, MDPI, vol. 13(1), pages 1-11, January.
    4. Enze Zhang & Jiang Liu & Chaohai Zhang & Peijun Zheng & Yosuke Nakanishi & Thomas Wu, 2023. "State-of-Art Review on Chemical Indicators for Monitoring the Aging Status of Oil-Immersed Transformer Paper Insulation," Energies, MDPI, vol. 16(3), pages 1-31, January.

    Corrections

    All material on this site has been provided by the respective publishers and authors. You can help correct errors and omissions. When requesting a correction, please mention this item's handle: RePEc:gam:jeners:v:12:y:2019:i:20:p:3969-:d:278094. See general information about how to correct material in RePEc.

    If you have authored this item and are not yet registered with RePEc, we encourage you to do it here. This allows to link your profile to this item. It also allows you to accept potential citations to this item that we are uncertain about.

    We have no bibliographic references for this item. You can help adding them by using this form .

    If you know of missing items citing this one, you can help us creating those links by adding the relevant references in the same way as above, for each refering item. If you are a registered author of this item, you may also want to check the "citations" tab in your RePEc Author Service profile, as there may be some citations waiting for confirmation.

    For technical questions regarding this item, or to correct its authors, title, abstract, bibliographic or download information, contact: MDPI Indexing Manager (email available below). General contact details of provider: https://www.mdpi.com .

    Please note that corrections may take a couple of weeks to filter through the various RePEc services.

    IDEAS is a RePEc service. RePEc uses bibliographic data supplied by the respective publishers.