Research on the Lightning Intruding Overvoltage and Protection Measures of 500 kV AC Fault Current Limiter

Author

Listed:
  • Changfu Chen

    (School of Electric Power, South China University of Technology, Guangzhou 510641, China)

  • Yongxia Han

    (School of Electric Power, South China University of Technology, Guangzhou 510641, China)

  • Junxiang Liu

    (Test & Research Institute of Guangzhou Power Supply Co., Ltd., Guangzhou 514010, China)

  • Wenxiong Mo

    (Test & Research Institute of Guangzhou Power Supply Co., Ltd., Guangzhou 514010, China)

  • Zhao Yuan

    (School of Electrical and Electronic Engineering, Huazhong University of Science and Technology, Wuhan 430074, China)

  • Jianning Huang

    (School of Electric Power, South China University of Technology, Guangzhou 510641, China)

  • Haibo Su

    (Test & Research Institute of Guangzhou Power Supply Co., Ltd., Guangzhou 514010, China)

  • Xiancong Zhang

    (Test & Research Institute of Guangzhou Power Supply Co., Ltd., Guangzhou 514010, China)

  • Kaijian Wu

    (School of Electrical and Electronic Engineering, Huazhong University of Science and Technology, Wuhan 430074, China)

Abstract

As one of the key technologies to solve the problem of high short-circuit current, the fault current limiter (FCL) has become a research hotspot in China and abroad. The overvoltage and protection measures of the FCL are the key technologies for its application. Therefore, this paper studies the lightning intruding overvoltage and protection measures for a 500 kV FCL based on a high coupled split reactor (HCSR). Firstly, according to the main topology of the system and the 500 kV HCSR-FCL structure, the lightning intruding overvoltage simulation model of the 500 kV station, including the nearby transmission lines, is established on the PSCAD (Power Systems Computer Aided Design) program. Secondly, the lightning overvoltage of the equipment in the station and the components of the HCSR-FCL are simulated and analyzed when the transmission lines nearby are subjected to lightning shielding failure and back flashover. Meanwhile, the influence of the HCSR-FCL on the lightning overvoltage of the equipment in the station are compared and analyzed before and after the HCSR-FCL is installed. The simulation results show that the overvoltage of the equipment in the station and the components of the HCSR-FCL is more serious when the shielding failure occurs in the transmission lines nearby. The HCSR-FCL can reduce the lightning overvoltage of the equipment in the station, but the maximum inter-terminal and inter-arm lightning overvoltage of the HCSR can reach 1064 kV and 790 kV, respectively, under the current limiting state and the current sharing state. Finally, methods of increasing the arresters on the transmission lines side of the HCSR-FCL and shunt capacitor between each module of the HCSR-FCL are proposed to reduce the lightning overvoltage. The lightning impulse withstand voltage of each component of the HCSR is also proposed: The inter-terminal lightning impulse withstand voltage of HCSR is 170 kV. The inter-arm lightning impulse withstand voltage of HCSR is 200 kV. The terminal-to-ground lightning impulse withstand voltage of the HCSR-FCL is 1550 kV.

Suggested Citation

  • Changfu Chen & Yongxia Han & Junxiang Liu & Wenxiong Mo & Zhao Yuan & Jianning Huang & Haibo Su & Xiancong Zhang & Kaijian Wu, 2019. "Research on the Lightning Intruding Overvoltage and Protection Measures of 500 kV AC Fault Current Limiter," Energies, MDPI, vol. 12(20), pages 1-17, October.
  • Handle: RePEc:gam:jeners:v:12:y:2019:i:20:p:3845-:d:275337
    as

    Download full text from publisher

    File URL: https://www.mdpi.com/1996-1073/12/20/3845/pdf
    Download Restriction: no

    File URL: https://www.mdpi.com/1996-1073/12/20/3845/
    Download Restriction: no
    ---><---

    Corrections

    All material on this site has been provided by the respective publishers and authors. You can help correct errors and omissions. When requesting a correction, please mention this item's handle: RePEc:gam:jeners:v:12:y:2019:i:20:p:3845-:d:275337. See general information about how to correct material in RePEc.

    If you have authored this item and are not yet registered with RePEc, we encourage you to do it here. This allows to link your profile to this item. It also allows you to accept potential citations to this item that we are uncertain about.

    We have no bibliographic references for this item. You can help adding them by using this form .

    If you know of missing items citing this one, you can help us creating those links by adding the relevant references in the same way as above, for each refering item. If you are a registered author of this item, you may also want to check the "citations" tab in your RePEc Author Service profile, as there may be some citations waiting for confirmation.

    For technical questions regarding this item, or to correct its authors, title, abstract, bibliographic or download information, contact: MDPI Indexing Manager (email available below). General contact details of provider: https://www.mdpi.com .

    Please note that corrections may take a couple of weeks to filter through the various RePEc services.

    IDEAS is a RePEc service. RePEc uses bibliographic data supplied by the respective publishers.