IDEAS home Printed from https://ideas.repec.org/a/gam/jeners/v12y2019i19p3703-d271581.html
   My bibliography  Save this article

Offshore Wind Farms On-Site Submarine Cable Testing and Diagnosis with Damped AC

Author

Listed:
  • Edward Gulski

    (Onsite hv solutions AG, Lucerne, Toepferstrasse 5, 6004 Lucerne, Switzerland)

  • Rogier Jongen

    (Onsite hv solutions AG, Lucerne, Toepferstrasse 5, 6004 Lucerne, Switzerland)

  • Aleksandra Rakowska

    (Institute of Electric Power Engineering, Poznan University of Technology, Piotrowo 3A, 60-965 Poznan, Poland)

  • Krzysztof Siodla

    (Institute of Electric Power Engineering, Poznan University of Technology, Piotrowo 3A, 60-965 Poznan, Poland)

Abstract

The current power cables IEC standards do not provide adequate recommendations for after-laying testing and diagnosis of offshore export and inter-array power cables. However the standards IEEE 400 and IEEE 400.4 recommend partial discharge monitored testing, e.g., by continuous or damped AC voltages (DAC). Based on the international experiences, as collected in more than 20 years at different power grids, this contribution focuses on the use of DAC for after-laying testing and diagnosis of submarine power cables both the export and inter-array cables. Higher risk of failure, long unavailability, higher repair costs, and maintenance costs imply that advanced quality control is becoming more important. The current state of the existing and drafting international standards are based on onshore experiences and not related to the actual serious problems experienced with failures on export up to 230 kV and inter-array cables up to 66 kV. The application of damped AC as a testing solution in this concern is specially discussed. The advantages of this testing technique, in combination with actual testing examples, show the findings on export and inter-array cables at offshore wind farms.

Suggested Citation

  • Edward Gulski & Rogier Jongen & Aleksandra Rakowska & Krzysztof Siodla, 2019. "Offshore Wind Farms On-Site Submarine Cable Testing and Diagnosis with Damped AC," Energies, MDPI, vol. 12(19), pages 1-14, September.
  • Handle: RePEc:gam:jeners:v:12:y:2019:i:19:p:3703-:d:271581
    as

    Download full text from publisher

    File URL: https://www.mdpi.com/1996-1073/12/19/3703/pdf
    Download Restriction: no

    File URL: https://www.mdpi.com/1996-1073/12/19/3703/
    Download Restriction: no
    ---><---

    Citations

    Citations are extracted by the CitEc Project, subscribe to its RSS feed for this item.
    as


    Cited by:

    1. Edward Gulski & George J. Anders & Rogier Jongen & Jaroslaw Parciak, 2022. "Damped AC Testing and Diagnosis of Wind Farm HVAC Long-Length Cable Circuits," Energies, MDPI, vol. 15(22), pages 1-17, November.
    2. Ioannis F. Gonos & Issouf Fofana, 2020. "Special Issue “Selected Papers from the 2018 IEEE International Conference on High Voltage Engineering (ICHVE 2018)”," Energies, MDPI, vol. 13(18), pages 1-5, September.

    Corrections

    All material on this site has been provided by the respective publishers and authors. You can help correct errors and omissions. When requesting a correction, please mention this item's handle: RePEc:gam:jeners:v:12:y:2019:i:19:p:3703-:d:271581. See general information about how to correct material in RePEc.

    If you have authored this item and are not yet registered with RePEc, we encourage you to do it here. This allows to link your profile to this item. It also allows you to accept potential citations to this item that we are uncertain about.

    We have no bibliographic references for this item. You can help adding them by using this form .

    If you know of missing items citing this one, you can help us creating those links by adding the relevant references in the same way as above, for each refering item. If you are a registered author of this item, you may also want to check the "citations" tab in your RePEc Author Service profile, as there may be some citations waiting for confirmation.

    For technical questions regarding this item, or to correct its authors, title, abstract, bibliographic or download information, contact: MDPI Indexing Manager (email available below). General contact details of provider: https://www.mdpi.com .

    Please note that corrections may take a couple of weeks to filter through the various RePEc services.

    IDEAS is a RePEc service. RePEc uses bibliographic data supplied by the respective publishers.