IDEAS home Printed from https://ideas.repec.org/a/gam/jeners/v11y2018i6p1430-d150406.html
   My bibliography  Save this article

Analysis and Improvement of Adaptive Coefficient Third Harmonic Voltage Differential Stator Grounding Protection

Author

Listed:
  • Ying Zhu

    (College of Energy and Electrical Engineering, Hohai University, Nanjing 211100, China)

  • Yuping Li

    (Nanjing SAC Power Grid Automation Co., Ltd., Nanjing 211100, China)

  • Jianbin Sang

    (Nanjing SAC Power Grid Automation Co., Ltd., Nanjing 211100, China)

  • Minglei Bao

    (Nanjing SAC Power Grid Automation Co., Ltd., Nanjing 211100, China)

  • Haixiang Zang

    (College of Energy and Electrical Engineering, Hohai University, Nanjing 211100, China)

Abstract

This paper presents a novel third harmonic voltage differential stator grounding protection (THV-DSGP) method combining the adaptive coefficient and fixed coefficient. It can solve the protection sensitivity degradation problem when the insulation resistance of stator winding to ground is slowly declining. This protection method retains the advantages of the adaptive coefficient, which is to maintain high sensitivity in case of an instantaneous ground fault. Moreover, the fixed coefficient can remember the initial insulation state of the stator winding and prevent relay failure when the stator insulation is slowly declining. In addition, due to zero-sequence voltage disconnection (ZSVD) often leading to malfunctioning of the THV stator ground protection, the existing criterion of the ZSVD was improved according to the electrical characteristics of the generator when ZSVD happens. THV-DSGP with both adaptive coefficient and fixed coefficient was simulated in the Matlab/Simulink. The simulation results show that the proposed protection can be applied to the slow ground fault of the stator winding. Furthermore, the improved criterion of ZSVD can effectively distinguish the stator metal earth fault and the secondary loop break of the zero-sequence voltage.

Suggested Citation

  • Ying Zhu & Yuping Li & Jianbin Sang & Minglei Bao & Haixiang Zang, 2018. "Analysis and Improvement of Adaptive Coefficient Third Harmonic Voltage Differential Stator Grounding Protection," Energies, MDPI, vol. 11(6), pages 1-15, June.
  • Handle: RePEc:gam:jeners:v:11:y:2018:i:6:p:1430-:d:150406
    as

    Download full text from publisher

    File URL: https://www.mdpi.com/1996-1073/11/6/1430/pdf
    Download Restriction: no

    File URL: https://www.mdpi.com/1996-1073/11/6/1430/
    Download Restriction: no
    ---><---

    References listed on IDEAS

    as
    1. Byung Eun Lee & Jinsik Lee & Sung Ho Won & Byongjun Lee & Peter A. Crossley & Yong Cheol Kang, 2014. "Saturation Detection-Based Blocking Scheme for Transformer Differential Protection," Energies, MDPI, vol. 7(7), pages 1-17, July.
    2. Xu Chen & Xianggen Yin & Bin Yu & Zhe Zhang, 2016. "Communication Channel Reconstruction for Transmission Line Differential Protection: System Arrangement and Routing Protocol," Energies, MDPI, vol. 9(11), pages 1-17, October.
    Full references (including those not matched with items on IDEAS)

    Citations

    Citations are extracted by the CitEc Project, subscribe to its RSS feed for this item.
    as


    Cited by:

    1. Xing Li & Fan Yang & Julan Ming & Ammad Jadoon & Sheng Han, 2018. "Imaging the Corrosion in Grounding Grid Branch with Inner-Source Electrical Impedance Tomography," Energies, MDPI, vol. 11(7), pages 1-13, July.
    2. Jingde Xia & Shaozhuo Li & Shuping Gao & Wenquan Shao & Guobing Song & Changjiang Chen, 2021. "Research on Differential Protection of Generator Based on New Braking Mode," Energies, MDPI, vol. 14(7), pages 1-16, March.

    Most related items

    These are the items that most often cite the same works as this one and are cited by the same works as this one.
    1. Lei Chen & Hongkun Chen & Jun Yang & Yanjuan Yu & Kaiwei Zhen & Yang Liu & Li Ren, 2017. "Coordinated Control of Superconducting Fault Current Limiter and Superconducting Magnetic Energy Storage for Transient Performance Enhancement of Grid-Connected Photovoltaic Generation System," Energies, MDPI, vol. 10(1), pages 1-23, January.
    2. Zhou Ruhan & Nurulafiqah Nadzirah Binti Mansor & Hazlee Azil Illias, 2023. "Identification of Inrush Current Using a GSA-BP Network," Energies, MDPI, vol. 16(5), pages 1-22, February.

    Corrections

    All material on this site has been provided by the respective publishers and authors. You can help correct errors and omissions. When requesting a correction, please mention this item's handle: RePEc:gam:jeners:v:11:y:2018:i:6:p:1430-:d:150406. See general information about how to correct material in RePEc.

    If you have authored this item and are not yet registered with RePEc, we encourage you to do it here. This allows to link your profile to this item. It also allows you to accept potential citations to this item that we are uncertain about.

    If CitEc recognized a bibliographic reference but did not link an item in RePEc to it, you can help with this form .

    If you know of missing items citing this one, you can help us creating those links by adding the relevant references in the same way as above, for each refering item. If you are a registered author of this item, you may also want to check the "citations" tab in your RePEc Author Service profile, as there may be some citations waiting for confirmation.

    For technical questions regarding this item, or to correct its authors, title, abstract, bibliographic or download information, contact: MDPI Indexing Manager (email available below). General contact details of provider: https://www.mdpi.com .

    Please note that corrections may take a couple of weeks to filter through the various RePEc services.

    IDEAS is a RePEc service. RePEc uses bibliographic data supplied by the respective publishers.