Author
Listed:
- Peng Li
(School of Electrical Engineering, Wuhan University, Wuhan 430072, China)
- Jiangjun Ruan
(School of Electrical Engineering, Wuhan University, Wuhan 430072, China)
- Daochun Huang
(School of Electrical Engineering, Wuhan University, Wuhan 430072, China)
- Ziqing OuYang
(School of Electrical Engineering, Wuhan University, Wuhan 430072, China)
- Li Zhang
(School of Electrical Engineering, Wuhan University, Wuhan 430072, China)
- Mingyang Long
(School of Electrical Engineering, Wuhan University, Wuhan 430072, China)
- Mengting Wei
(School of Electrical Engineering, Wuhan University, Wuhan 430072, China)
Abstract
When an arc fault occurs in a medium-voltage (MV) metal enclosed switchgear, the arc heats the filling gas, resulting in a pressure rise, which may seriously damage the switchgear, the building it is contained in, or even endanger maintenance personnel. A pressure rise calculation method based on computational fluid dynamics (CFD) has been put forward in this paper. The pressure rise was calculated and the arc tests between the copper electrodes were performed in the container under different gap lengths by the current source. The results show that the calculated pressure rise agrees well with the measurement, and the relative error of the average pressure rise is about 2%. Arc volume has less effect on the pressure distribution in the container. Arc voltage Root-Mean-Square (RMS) has significant randomness with the change of arc current, and increases with the increase of gap length. The average arc voltage gradients measure at about 26, 20 and 16 V/cm when the gap lengths are 5, 10 and 15 cm, respectively. The proportion (thermal transfer coefficient k p ) of the arc energy leading to the pressure rise in the container is about 44.9%. The pressure is symmetrically distributed in the container before the pressure wave reaches the walls and the process of the energy release is similar to an explosion. The maximum overpressure in the corner is increased under the reflection and superimposition effects of the pressure wave, but the pressure waves will be of no importance any longer than a few milliseconds in the closed container.
Suggested Citation
Peng Li & Jiangjun Ruan & Daochun Huang & Ziqing OuYang & Li Zhang & Mingyang Long & Mengting Wei, 2017.
"Analysis of Pressure Rise in a Closed Container Due to Internal Arcing,"
Energies, MDPI, vol. 10(3), pages 1-17, March.
Handle:
RePEc:gam:jeners:v:10:y:2017:i:3:p:294-:d:91938
Download full text from publisher
Corrections
All material on this site has been provided by the respective publishers and authors. You can help correct errors and omissions. When requesting a correction, please mention this item's handle: RePEc:gam:jeners:v:10:y:2017:i:3:p:294-:d:91938. See general information about how to correct material in RePEc.
If you have authored this item and are not yet registered with RePEc, we encourage you to do it here. This allows to link your profile to this item. It also allows you to accept potential citations to this item that we are uncertain about.
We have no bibliographic references for this item. You can help adding them by using this form .
If you know of missing items citing this one, you can help us creating those links by adding the relevant references in the same way as above, for each refering item. If you are a registered author of this item, you may also want to check the "citations" tab in your RePEc Author Service profile, as there may be some citations waiting for confirmation.
For technical questions regarding this item, or to correct its authors, title, abstract, bibliographic or download information, contact: MDPI Indexing Manager (email available below). General contact details of provider: https://www.mdpi.com .
Please note that corrections may take a couple of weeks to filter through
the various RePEc services.