IDEAS home Printed from https://ideas.repec.org/a/gam/jchals/v12y2021i2p33-d694998.html
   My bibliography  Save this article

Considering Existing Factors That May Cause Radiation Hormesis at <100 mSv and Obey the Linear No-Threshold Theory at ≥100 mSv

Author

Listed:
  • Katsuhito Kino

    (Kagawa School of Pharmaceutical Sciences, Tokushima Bunri University, 1314-1 Shido, Sanuki 769-2193, Japan)

  • Takayuki Ohshima

    (Faculty of Science and Engineering, Tokushima Bunri University, 1314-1 Shido, Sanuki 769-2193, Japan)

  • Hajime Takeuchi

    (Kagawa School of Pharmaceutical Sciences, Tokushima Bunri University, 1314-1 Shido, Sanuki 769-2193, Japan)

  • Takanobu Kobayashi

    (Kagawa School of Pharmaceutical Sciences, Tokushima Bunri University, 1314-1 Shido, Sanuki 769-2193, Japan)

  • Taishu Kawada

    (Kagawa School of Pharmaceutical Sciences, Tokushima Bunri University, 1314-1 Shido, Sanuki 769-2193, Japan)

  • Masayuki Morikawa

    (Kagawa School of Pharmaceutical Sciences, Tokushima Bunri University, 1314-1 Shido, Sanuki 769-2193, Japan)

  • Hiroshi Miyazawa

    (Kagawa School of Pharmaceutical Sciences, Tokushima Bunri University, 1314-1 Shido, Sanuki 769-2193, Japan)

Abstract

The linear no-threshold (LNT) theory describes the linear relationship between a radiation dose and its effects. However, whether the linear relationship is maintained at low radiation doses has yet to be determined. Many previous studies support the radiation hormesis theory, which states that radiation has beneficial effects on health. In this viewpoint, we propose a mathematical function fitted to a model consistent with both the LNT at ≥100 mSv and radiation hormesis theories at <100 mSv, and the model requires a factor whose amount or activity takes a mountain-like shape versus the radiation dose and have one maximum value at 40.9 mSv. We searched a wide range of factors with these features based on searches on PubMed, and then evaluated whether these factors were suitable candidates consistent with both the LNT and radiation hormesis theories. Our consideration indicated that these factors did not completely follow the equation suggested at this time. Of course, other theories do not deny that these factors are involved in hormesis. However, based on our theory, still unknown factors may be involved in radiation hormesis, and then such unknown factors which are activated at <100 mSv should be searched.

Suggested Citation

  • Katsuhito Kino & Takayuki Ohshima & Hajime Takeuchi & Takanobu Kobayashi & Taishu Kawada & Masayuki Morikawa & Hiroshi Miyazawa, 2021. "Considering Existing Factors That May Cause Radiation Hormesis at <100 mSv and Obey the Linear No-Threshold Theory at ≥100 mSv," Challenges, MDPI, vol. 12(2), pages 1-11, December.
  • Handle: RePEc:gam:jchals:v:12:y:2021:i:2:p:33-:d:694998
    as

    Download full text from publisher

    File URL: https://www.mdpi.com/2078-1547/12/2/33/pdf
    Download Restriction: no

    File URL: https://www.mdpi.com/2078-1547/12/2/33/
    Download Restriction: no
    ---><---

    Corrections

    All material on this site has been provided by the respective publishers and authors. You can help correct errors and omissions. When requesting a correction, please mention this item's handle: RePEc:gam:jchals:v:12:y:2021:i:2:p:33-:d:694998. See general information about how to correct material in RePEc.

    If you have authored this item and are not yet registered with RePEc, we encourage you to do it here. This allows to link your profile to this item. It also allows you to accept potential citations to this item that we are uncertain about.

    We have no bibliographic references for this item. You can help adding them by using this form .

    If you know of missing items citing this one, you can help us creating those links by adding the relevant references in the same way as above, for each refering item. If you are a registered author of this item, you may also want to check the "citations" tab in your RePEc Author Service profile, as there may be some citations waiting for confirmation.

    For technical questions regarding this item, or to correct its authors, title, abstract, bibliographic or download information, contact: MDPI Indexing Manager (email available below). General contact details of provider: https://www.mdpi.com .

    Please note that corrections may take a couple of weeks to filter through the various RePEc services.

    IDEAS is a RePEc service. RePEc uses bibliographic data supplied by the respective publishers.