Author
Listed:
- Xiaoshuai Wang
(College of Biosystems Engineering and Food Science, Zhejiang University, Hangzhou 310058, China)
- Mengbing Cao
(College of Biosystems Engineering and Food Science, Zhejiang University, Hangzhou 310058, China)
- Feiyue Hu
(College of Biosystems Engineering and Food Science, Zhejiang University, Hangzhou 310058, China)
- Qianying Yi
(Department of Engineering for Livestock Management, Leibniz Institute for Agricultural Engineering and Bioeconomy (ATB), Max-Eyth-Allee 100, 14469 Potsdam, Germany)
- Thomas Amon
(Department of Engineering for Livestock Management, Leibniz Institute for Agricultural Engineering and Bioeconomy (ATB), Max-Eyth-Allee 100, 14469 Potsdam, Germany
Department of Veterinary Medicine, Institute of Animal Hygiene and Environmental Health, Free University Berlin, Robert-von-Ostertag-Str. 7–13, 14163 Berlin, Germany)
- David Janke
(Department of Veterinary Medicine, Institute of Animal Hygiene and Environmental Health, Free University Berlin, Robert-von-Ostertag-Str. 7–13, 14163 Berlin, Germany)
- Tian Xie
(Qingdao Big Herdsman Machinery Co., Ltd., Qingdao 266000, China)
- Guoqiang Zhang
(Department of Engineering, Aarhus University, Inge Lehmanns Gade 10, 8000 Aarhus, Denmark)
- Kaiying Wang
(College of Biosystems Engineering and Food Science, Zhejiang University, Hangzhou 310058, China)
Abstract
An increasing number of large pig farms are being built in multi-floor pig buildings (MFPBs) in China. Currently, the ventilation system of MFPB varies greatly and lacks common standards. This work aims to compare the ventilation performance of three popular MFPB types with different placement of fans using the Computational Fluid Dynamics (CFD) technique. After being validated with field-measured data, the CFD models were extended to simulate the air velocity, air temperature, humidity, and effective temperature of the three MFPBs. The simulation results showed that the ventilation rate of the building with outflowing openings in the endwall and fans installed on the top of the shaft was approximately 25% less than the two buildings with fans installed on each floor. The ventilation rate of each floor increased from the first to the top floor for both buildings with a shaft, while no significant difference was observed in the building without a shaft. Increasing the shaft’s width could mitigate the variation in the ventilation rate of each floor. The effective temperature distribution at the animal level was consistent with the air velocity distribution. Therefore, in terms of the indoor environmental condition, the fans were recommended to be installed separately on each floor.
Suggested Citation
Xiaoshuai Wang & Mengbing Cao & Feiyue Hu & Qianying Yi & Thomas Amon & David Janke & Tian Xie & Guoqiang Zhang & Kaiying Wang, 2022.
"Effect of Fans’ Placement on the Indoor Thermal Environment of Typical Tunnel-Ventilated Multi-Floor Pig Buildings Using Numerical Simulation,"
Agriculture, MDPI, vol. 12(6), pages 1-15, June.
Handle:
RePEc:gam:jagris:v:12:y:2022:i:6:p:891-:d:843312
Download full text from publisher
Corrections
All material on this site has been provided by the respective publishers and authors. You can help correct errors and omissions. When requesting a correction, please mention this item's handle: RePEc:gam:jagris:v:12:y:2022:i:6:p:891-:d:843312. See general information about how to correct material in RePEc.
If you have authored this item and are not yet registered with RePEc, we encourage you to do it here. This allows to link your profile to this item. It also allows you to accept potential citations to this item that we are uncertain about.
We have no bibliographic references for this item. You can help adding them by using this form .
If you know of missing items citing this one, you can help us creating those links by adding the relevant references in the same way as above, for each refering item. If you are a registered author of this item, you may also want to check the "citations" tab in your RePEc Author Service profile, as there may be some citations waiting for confirmation.
For technical questions regarding this item, or to correct its authors, title, abstract, bibliographic or download information, contact: MDPI Indexing Manager (email available below). General contact details of provider: https://www.mdpi.com .
Please note that corrections may take a couple of weeks to filter through
the various RePEc services.