IDEAS home Printed from https://ideas.repec.org/a/eee/energy/v313y2024ics0360544224035448.html
   My bibliography  Save this article

Thermal-hydraulic characteristics of an earth air heat exchanger: An experimental analysis

Author

Listed:
  • El-Said, Emad M.S.

Abstract

The pipe layout design has a great effect on the thermal-hydraulic characteristics of earth air heat exchanger (EAHE) systems. So, in the current study proposed four new buried pipe design configurations; low to high to low, high to low to high, spiral, and circular, in addition to the straight or uniform for comparison. These five configurations are tested and analyzed experimentally depending on the thermo-hydraulic performance for summer cooling requirements with variation of Re in the range of 18041–40843. The results show that changing the uniform design of the EAHE with fixed pipe length enhances both the heat transfer process and pressure loss values. At the same operating conditions, the circular design has the best performance compared to the other ones. For all pipe shapes, the cooling effect increases with the increase of air Re. The thermal-hydraulic performance of the circular design pipe is higher than that of the other pipe designs. The highest coefficient of performance (COP) average values that can be obtained at Re = 18041 is 3.05 for circular shape and enhances by 48.08 % compared to uniform shape. The effectiveness of EAHE with circular shape is improved by about 3.52 % compared to uniform shape at Re = 18041. Spiral design is optimum design based on the Nu value which reaches about 48 with enhancement 12.56 % and 0.34 % compared to uniform and circular shapes respectively, at Re = 40843. The hydrothermal performance factor is highest in the case of circular shape with value about 21.9 at Re = 21257. By increasing Re, the drawbacks of the increasing in the total entropy generation are reflected negatively on the exergy efficiency. The specific cost of the circular shape at Re = 40843 is the optimum value by about 0.7 $/W. Spiral and circular shapes have a decrease of CO2 emissions less than uniform shape by percentage varied from 2.93 % to 13.84 % for decrease in the Re from 21257 to 40843. It is concluded that using EAHE with four new shapes is highly efficient in increasing cooling capacity and energy consumption in buildings.

Suggested Citation

  • El-Said, Emad M.S., 2024. "Thermal-hydraulic characteristics of an earth air heat exchanger: An experimental analysis," Energy, Elsevier, vol. 313(C).
  • Handle: RePEc:eee:energy:v:313:y:2024:i:c:s0360544224035448
    DOI: 10.1016/j.energy.2024.133766
    as

    Download full text from publisher

    File URL: http://www.sciencedirect.com/science/article/pii/S0360544224035448
    Download Restriction: Full text for ScienceDirect subscribers only

    File URL: https://libkey.io/10.1016/j.energy.2024.133766?utm_source=ideas
    LibKey link: if access is restricted and if your library uses this service, LibKey will redirect you to where you can use your library subscription to access this item
    ---><---

    As the access to this document is restricted, you may want to search for a different version of it.

    Corrections

    All material on this site has been provided by the respective publishers and authors. You can help correct errors and omissions. When requesting a correction, please mention this item's handle: RePEc:eee:energy:v:313:y:2024:i:c:s0360544224035448. See general information about how to correct material in RePEc.

    If you have authored this item and are not yet registered with RePEc, we encourage you to do it here. This allows to link your profile to this item. It also allows you to accept potential citations to this item that we are uncertain about.

    We have no bibliographic references for this item. You can help adding them by using this form .

    If you know of missing items citing this one, you can help us creating those links by adding the relevant references in the same way as above, for each refering item. If you are a registered author of this item, you may also want to check the "citations" tab in your RePEc Author Service profile, as there may be some citations waiting for confirmation.

    For technical questions regarding this item, or to correct its authors, title, abstract, bibliographic or download information, contact: Catherine Liu (email available below). General contact details of provider: http://www.journals.elsevier.com/energy .

    Please note that corrections may take a couple of weeks to filter through the various RePEc services.

    IDEAS is a RePEc service. RePEc uses bibliographic data supplied by the respective publishers.