IDEAS home Printed from https://ideas.repec.org/a/eee/energy/v291y2024ics0360544224001154.html
   My bibliography  Save this article

Successful application of predictive information in deep reinforcement learning control: A case study based on an office building HVAC system

Author

Listed:
  • Gao, Yuan
  • Shi, Shanrui
  • Miyata, Shohei
  • Akashi, Yasunori

Abstract

Reinforcement Learning (RL), a promising algorithm for the operational control of Heating, Ventilation, and Air Conditioning (HVAC) systems, has garnered considerable attention and applications. However, traditional RL algorithms typically do not incorporate predictive information for future scenarios, and only a limited number of studies have examined the enhancement and impact of predictive information on RL algorithms. To address the issue of coupling RL and predictive information in HVAC system operation optimization, we employed an open-source framework to examine the impact of various predictive information strategies on RL outcomes. We propose a joint gated recurrent unit (GRU)-RL algorithm to handle situations where a time-series exists in state space. The results from four classic test cases demonstrate that the proposed GRU-RL method can reduce operating costs by approximately 14.5% and increase comfort performance by 88.4% in indoor comfort control and cost-management tasks. Moreover, the GRU-RL method outperformed the conventional DRL method and was merely augmented with prediction information. In indoor temperature regulation, the GRU-RL algorithm improves control efficacy by 14.2% compared to models without predictive information and offers an approximately 5% improvement over traditional network models. Finally, all models were made open source for easy replication and further research.

Suggested Citation

  • Gao, Yuan & Shi, Shanrui & Miyata, Shohei & Akashi, Yasunori, 2024. "Successful application of predictive information in deep reinforcement learning control: A case study based on an office building HVAC system," Energy, Elsevier, vol. 291(C).
  • Handle: RePEc:eee:energy:v:291:y:2024:i:c:s0360544224001154
    DOI: 10.1016/j.energy.2024.130344
    as

    Download full text from publisher

    File URL: http://www.sciencedirect.com/science/article/pii/S0360544224001154
    Download Restriction: Full text for ScienceDirect subscribers only

    File URL: https://libkey.io/10.1016/j.energy.2024.130344?utm_source=ideas
    LibKey link: if access is restricted and if your library uses this service, LibKey will redirect you to where you can use your library subscription to access this item
    ---><---

    As the access to this document is restricted, you may want to search for a different version of it.

    Citations

    Citations are extracted by the CitEc Project, subscribe to its RSS feed for this item.
    as


    Cited by:

    1. Morovat, Navid & Athienitis, Andreas K. & Candanedo, José Agustín & Nouanegue, Hervé Frank, 2024. "Heuristic model predictive control implementation to activate energy flexibility in a fully electric school building," Energy, Elsevier, vol. 296(C).

    Corrections

    All material on this site has been provided by the respective publishers and authors. You can help correct errors and omissions. When requesting a correction, please mention this item's handle: RePEc:eee:energy:v:291:y:2024:i:c:s0360544224001154. See general information about how to correct material in RePEc.

    If you have authored this item and are not yet registered with RePEc, we encourage you to do it here. This allows to link your profile to this item. It also allows you to accept potential citations to this item that we are uncertain about.

    We have no bibliographic references for this item. You can help adding them by using this form .

    If you know of missing items citing this one, you can help us creating those links by adding the relevant references in the same way as above, for each refering item. If you are a registered author of this item, you may also want to check the "citations" tab in your RePEc Author Service profile, as there may be some citations waiting for confirmation.

    For technical questions regarding this item, or to correct its authors, title, abstract, bibliographic or download information, contact: Catherine Liu (email available below). General contact details of provider: http://www.journals.elsevier.com/energy .

    Please note that corrections may take a couple of weeks to filter through the various RePEc services.

    IDEAS is a RePEc service. RePEc uses bibliographic data supplied by the respective publishers.