Author
Listed:
- Benjamin Panzram
- Ines Bertlich
- Tobias Reiner
- Tilman Walker
- Sébastien Hagmann
- Marc-André Weber
- Tobias Gotterbarm
Abstract
Purpose: Tibial radiolucent lines (RL) are commonly seen in cemented unicompartmental knee replacement (UKR). In the postoperative course, they can be misinterpreted as signs of loosening, thus leading to unnecessary revision. Since 2004, a cementless OUKR is available. First studies and registry data have shown equally good clinical results of cementless OUKR compared to the cemented version and a significantly reduced incidence of RL in cementless implants. Methods: This single-centre retrospective cohort study includes the first 30 UKR (27 patients) implanted between 2007 and 2009 with a mean follow-up of 5 years. Clinical outcome was evaluated using the OKS, AKS, range of movement (ROM) and level of pain (VAS). Standard radiologic evaluation was performed at three months, one and five years after surgery. The results five years after implantation were compared to a group of 27 cemented Oxford UKR (OUKR) in a matched-pair-analysis. Results: Tibial RL were seen in 10 implants three months after operation, which significantly decreased to five after one year and to three after five years (p = 0.02). RL did not have a significant influence on revision (p = 1.0) or clinical outcome after five years. RL were always partial, never progressive and strictly limited to the tibia. There was no significant difference in the incidence of tibial RL five years after implantation between cemented and cementless implants (cemented: 4, cementless: 3, p = 1.0). Conclusions: After cementless implantation RL were limited to the tibia, partial and never progressive. During short term follow-up the incidence of RL decreased significantly. RL seem to have no influence on clinical outcome and revision.
Suggested Citation
Benjamin Panzram & Ines Bertlich & Tobias Reiner & Tilman Walker & Sébastien Hagmann & Marc-André Weber & Tobias Gotterbarm, 2017.
"Results after Cementless Medial Oxford Unicompartmental Knee Replacement - Incidence of Radiolucent Lines,"
PLOS ONE, Public Library of Science, vol. 12(1), pages 1-9, January.
Handle:
RePEc:plo:pone00:0170324
DOI: 10.1371/journal.pone.0170324
Download full text from publisher
Corrections
All material on this site has been provided by the respective publishers and authors. You can help correct errors and omissions. When requesting a correction, please mention this item's handle: RePEc:plo:pone00:0170324. See general information about how to correct material in RePEc.
If you have authored this item and are not yet registered with RePEc, we encourage you to do it here. This allows to link your profile to this item. It also allows you to accept potential citations to this item that we are uncertain about.
We have no bibliographic references for this item. You can help adding them by using this form .
If you know of missing items citing this one, you can help us creating those links by adding the relevant references in the same way as above, for each refering item. If you are a registered author of this item, you may also want to check the "citations" tab in your RePEc Author Service profile, as there may be some citations waiting for confirmation.
For technical questions regarding this item, or to correct its authors, title, abstract, bibliographic or download information, contact: plosone (email available below). General contact details of provider: https://journals.plos.org/plosone/ .
Please note that corrections may take a couple of weeks to filter through
the various RePEc services.