Author
Listed:
- Tian Zhao
- Huifang Yang
- Huaxin Sui
- Satyajeet Sudhir Salvi
- Yong Wang
- Yuchun Sun
Abstract
Objective: Developments in digital technology have permitted researchers to study mandibular movements. Here, the accuracy of a real-time, computerized, binocular, three-dimensional (3D) trajectory-tracking device for recording functional mandibular movements was evaluated. Methods: An occlusal splint without the occlusal region was created based on a plaster cast of the lower dentition. The splint was rigidly connected with a target on its labial side and seated on the cast. The cast was then rigidly attached to the stage of a high-precision triaxial electronic translator, which was used to move the target-cast-stage complex. Half-circular movements (5.00-mm radius) in three planes (XOY, XOZ, YOZ) and linear movements along the x-axis were performed at 5.00 mm/s. All trajectory points were recorded with the binocular 3D trajectory-tracking device and fitted to arcs or lines, respectively, with the Imageware software. To analyze the accuracy of the trajectory-tracking device, the mean distances between the trajectory points and the fitted arcs or lines were measured, and the mean differences between the lengths of the fitted arcs’ radii and a set value (5.00 mm) were then calculated. A one-way analysis of variance was used to evaluate the spatial consistency of the recording accuracy in three different planes. Results: The mean distances between the trajectory points and fitted arcs or lines were 0.076 ± 0.033 mm or 0.089 ± 0.014 mm. The mean difference between the lengths of the fitted arcs’ radii and the set value (5.00 mm) was 0.025 ± 0.071 mm. A one-way ANOVA showed that the recording errors in three different planes were not statistically significant. Conclusion: These results suggest that the device can record certain movements at 5.00 mm/s, which is similar to the speed of functional mandibular movements. In addition, the recordings had an error of
Suggested Citation
Tian Zhao & Huifang Yang & Huaxin Sui & Satyajeet Sudhir Salvi & Yong Wang & Yuchun Sun, 2016.
"Accuracy of a Real-Time, Computerized, Binocular, Three-Dimensional Trajectory-Tracking Device for Recording Functional Mandibular Movements,"
PLOS ONE, Public Library of Science, vol. 11(10), pages 1-8, October.
Handle:
RePEc:plo:pone00:0163934
DOI: 10.1371/journal.pone.0163934
Download full text from publisher
Corrections
All material on this site has been provided by the respective publishers and authors. You can help correct errors and omissions. When requesting a correction, please mention this item's handle: RePEc:plo:pone00:0163934. See general information about how to correct material in RePEc.
If you have authored this item and are not yet registered with RePEc, we encourage you to do it here. This allows to link your profile to this item. It also allows you to accept potential citations to this item that we are uncertain about.
We have no bibliographic references for this item. You can help adding them by using this form .
If you know of missing items citing this one, you can help us creating those links by adding the relevant references in the same way as above, for each refering item. If you are a registered author of this item, you may also want to check the "citations" tab in your RePEc Author Service profile, as there may be some citations waiting for confirmation.
For technical questions regarding this item, or to correct its authors, title, abstract, bibliographic or download information, contact: plosone (email available below). General contact details of provider: https://journals.plos.org/plosone/ .
Please note that corrections may take a couple of weeks to filter through
the various RePEc services.